SACC-SQ-M12MS-17CON-20/0,5 1441723 PHOENIX CONTACT Flush-type connector
SACC-SQ-M12MS-17CON-20/0,5
1441723
PHOENIX CONTACT
1 Pcs.
Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact SACC-SQ-M12MS-17CON-20/0,5 is a multi-contact flush-type connector built for high-density signal integration in complex control architecture. Flanged connectors provide a secure mechanical anchor point for internal device wiring in industrial machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Cable length (EF000536): 0.5 mm
- Mounting method (EF000003): Front mounting
- Ambient temperature (EF002386): 85 °C
- Operating temperature (EF002393): -25 °C
- Rated voltage (EF000228): 30 V
- With shield connection (EF002535): No
- Screw-in thread (EF012303): M12
- Core cross section (EF000018): 0.14 mm²
- Min. number of insertion cycles (EF012212): 100
- Degree of protection (IP), mounted (EF007466): IP67
More info
▲Key Commercial Data
| Orderkey | 1441723 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 38 (C-2-2017) |
| GTIN | 4046356533065 |
| Weight per Piece (excluding packing) | 31.300 g |
| Custom tariff number | 85444290 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
|---|---|
| -40 °C ... 85 °C (without mechanical actuation) | |
| Degree of protection | IP67 |
General
| Note | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
|---|---|
| Rated current at 40°C | 1.5 A |
| Rated voltage | 30 V |
| Rated surge voltage | 0.8 kV |
| Number of positions | 17 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Connection method | Individual wires |
| Insertion/withdrawal cycles | > 100 |
| Torque | 3 Nm ... 4 Nm (Installation-side) |
| Mounting type | Front mounting Square flange 20 mm side length |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | PA 6.6 |
| Material of grip body | Zinc die-cast, nickel-plated |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | FKM |
Cable
| Cable type | TPE litz wire |
|---|---|
| Conductor cross section | 0.14 mm² |
| Conductor structure signal line | 7x 0.16 mm |
| Core diameter including insulation | 1.1 mm ±0.05 mm |
| Thickness, insulation | 0.21 mm (Core insulation) |
| Wire colors | brown, blue, white, green, pink, yellow, black, gray, red, violet, gray/pink, red/blue, white/green, brown/green, white/yellow, yellow/brown, white/gray |
| Material conductor insulation | TPE |
| Conductor material | Tin-plated Cu litz wires |
| Standards/specifications | M12 connector IEC 61076-2-101 |
| Insulation resistance | ≥ 20 MΩ*km |
| Conductor resistance | ≤ 57.6 mΩ/m |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 2000 V AC |
| Ambient temperature (operation) | -40 °C ... 85 °C (cable, fixed installation) |
| -25 °C ... 85 °C (cable, flexible installation) |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |