FLKM-2KS50/BFI/MKDS/CS 2900162 PHOENIX CONTACT Passive module
FLKM-2KS50/BFI/MKDS/CS
2900162
PHOENIX CONTACT
1 Pcs.
Automation > Interface module
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact FLKM-2KS50/BFI/MKDS/CS passive module serves as a dedicated interface component for linking specific control system I/O cards to field instrumentation. Engineers deploy these pre-wired passive interface blocks to eliminate errors and expedite commissioning in large-scale industrial automation plants. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Interface module
- No. of channels: 32
- Operating mode: 100% operating factor
- Data management status Article revision: 04
- Insulation characteristics Insulation: Functional insulation
- Overvoltage category: II
- Pollution degree: 2
- Nominal voltage U N: 24 V DC
- Max. current carrying capacity per branch: 100 mA (observe derating)
- Max. total current of all branches: 4 A (observe derating)
- Rated insulation voltage: 50 V DC
- Rated surge voltage: 0.5 kV
- Supported controller YOKOGAWA STARDOM Suitable I/O card: NFDV151
- Contact switching type: 1 N/O contact
- Type of switch contact: Double contact
- Contact material: AgNi, 5 µm hard gold-plated
More info
▲| Product type | Interface module |
| No. of channels | 32 |
| Operating mode | 100% operating factor |
| Data management status | |
| Article revision | 04 |
| Insulation characteristics | |
| Insulation | Functional insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Nominal voltage UN | 24 V DC |
| 19.2 V DC ... 26.4 V DC | |
| Max. current carrying capacity per branch | 100 mA (observe derating) |
| Max. total current of all branches | 4 A (observe derating) |
| Rated insulation voltage | 50 V DC |
| Rated surge voltage | 0.5 kV |
| Supported controller YOKOGAWA CS3000 CentumVP | |
| Suitable I/O card | ADV151 |
| ADV161 | |
| ADV551 | |
| ADV561 | |
| Supported controller YOKOGAWA STARDOM | |
| Suitable I/O card | NFDV151 |
| NFDV161 | |
| NFDV551 | |
| NFDV561 | |
| Contact switching type | 1 N/O contact |
| Type of switch contact | Double contact |
| Contact material | AgNi, 5 µm hard gold-plated |
| Maximum switching voltage | < 25 V AC |
| 48 V DC | |
| Limiting continuous current | 1 A |
| Min. switching current | 1 mA |
| Interrupting rating (ohmic load) max. | 24 W (24 V DC) |
| 48 W (48 V DC) | |
| 25 VA (25 V AC) | |
| Mechanical service life | approx. 2x 107cycles |
| Field level | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 m² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Controller level | |
| Connection method | Yokogawa KS-compatible |
| Number of connections | 2 |
| Number of positions | 50 |
| Note | Usable system cables: Phoenix Contact YUC50, Yokogawa AKB331 |
| Tightening torque | 0.5 Nm |
| Status display | LED (red) |
| Status display present | Yes, if the fuse fails |
| Operating voltage display | Green LED |
| Item dimensions | |
| Width | 343.1 mm |
| Height | 111.9 mm |
| Depth | 65.15 mm |
| Ambient conditions | |
| Degree of protection | IP00 |
| Ambient temperature (operation) | -20 °C ... 65 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Altitude | ≤ 2000 m |
| Standards/regulations | EN IEC 60664-1 |
| Mounting type | DIN rail mounting |
| Assembly note | in rows with zero spacing |
| Mounting position | any |
| Notes on operation | Voltage monitoring on the module does not work in combination with upstream HESILED fuse terminal blocks with integrated LED display. |
| Notes on operation | Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. |
| Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). |
| Notes on operation | Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e. g. partition plates). |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |