View larger
FLKM-2KS50/32DO/YCS/ZFKDS 2901200 PHOENIX CONTACT 32-channel output module with spring-cage connection. The ..
FLKM-2KS50/32DO/YCS/ZFKDS
2901200
PHOENIX CONTACT
1 Pcs.
Automation > Interface module
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A FLKM-2KS50/32DO/YCS/ZFKDS output module by Phoenix Contact manages multi-channel digital signal distribution for Yokogawa system architectures. These interface units provide organized termination points that protect sensitive automation equipment from common wiring faults. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Interface module
- Operating mode: 100% operating factor
- Overvoltage category: II
- Pollution degree: 2
- Max. permissible operating voltage: 30 V DC
- Max. permissible current: 100 mA (per path)
- Max. permissible total current: 4 A (Protected by slow-blow fuse 4 A, 5x20 (short-circuit protection only))
- Nominal voltage U N: 24 V DC
- Max. total current of all branches: 4 A
- Rated surge voltage: 0.5 kV
- Field level Connection method: Spring-cage connection
- Stripping length: 8 mm
- Conductor cross section rigid: 0.2 mm² ... 4 mm²
- Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
- Conductor cross section AWG: 24 ... 12
- Controller level Connection method: Yokogawa KS-compatible
More info
▲| Product type | Interface module |
| Operating mode | 100% operating factor |
| Insulation characteristics: Air clearances and creepage distances between the power circuits | |
| Insulation | Functional insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Max. permissible operating voltage | 30 V DC |
| Max. permissible current | 100 mA (per path) |
| Max. permissible total current | 4 A (Protected by slow-blow fuse 4 A, 5x20 (short-circuit protection only)) |
| Nominal voltage UN | 24 V DC |
| Max. total current of all branches | 4 A |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 50 V |
| Rated surge voltage | 0.5 kV |
| Supported controller YOKOGAWA CS3000 CentumVP | |
| Suitable I/O card | ADV551 |
| Field level | |
| Connection method | Spring-cage connection |
| Stripping length | 8 mm |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Controller level | |
| Connection method | Yokogawa KS-compatible |
| Number of connections | 2 |
| Number of positions | 50 |
| Tightening torque | 0.5 Nm |
| Status display present | Yes |
| Operating voltage display | Green LED |
| Item dimensions | |
| Width | 180 mm |
| Height | 90 mm |
| Depth | 77 mm |
| Ambient conditions | |
| Degree of protection | IP00 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Altitude | ≤ 2000 m |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | EN IEC 60664-1 |
| Mounting type | DIN rail mounting |
| Assembly note | in rows with zero spacing |
| Mounting position | any |
| Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). |
| Notes on operation | At least one functional insulation against adjacent modules is complied with (in the support rail direction). If the application has stricter requirements for the insulation (basic insulation or reinforced insulation), they must be realized by applying suitable measures (e. g. partition plates). |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |