View larger
FLK 50-PA/EZ-DR/KS/1500/YOC 2314435 PHOENIX CONTACT Front adapters
FLK 50-PA/EZ-DR/KS/1500/YOC
2314435
PHOENIX CONTACT
1 Pcs.
Automation > Accessories/spare parts for controls
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact FLK 50-PA/EZ-DR/KS/1500/YOC is a front adapter designed to interface control signals between specialized I/O cards and field-level cabling systems in automated process facilities. Front adapters streamline system integration by providing reliable, pre-wired or modular connections from complex controllers directly to marshalling panels, reducing wiring errors and installation time. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Front adapter
- Data management status Article revision: 10
- Operating voltage (DC): ≤ 30 V DC
- Nominal operating mode: 100% operating factor
- Current (Per path): ≤ 500 mA (uncoiled)
- Supported controller YOKOGAWA ProSafe-RS Suitable I/O card: SDV531
- Connection 1 Connection in acc. with standard: based on IEC 60603-13
- Connection method: Yokogawa, I/O cards compatible
- Number of connections: 1
- Number of positions: 50
- Tightening torque: 0.5 Nm (Screw connection)
- Insertion/withdrawal cycles: > 50
- Pitch: 2.54 mm
- Connection 2 Connection in acc. with standard: based on IEC 60603-13
- Connection method: Yokogawa, KS compatible
- Number of connections: 1
More info
▲| Product type | Front adapter |
| Data management status | |
| Article revision | 10 |
| Operating voltage (DC) | ≤ 30 V DC |
| Nominal operating mode | 100% operating factor |
| Current (Per path) | ≤ 500 mA (uncoiled) |
| Supported controller YOKOGAWA ProSafe-RS | |
| Suitable I/O card | SDV531 |
| SDV531L | |
| Connection 1 | |
| Connection in acc. with standard | based on IEC 60603-13 |
| Connection method | Yokogawa, I/O cards compatible |
| Number of connections | 1 |
| Number of positions | 50 |
| Tightening torque | 0.5 Nm (Screw connection) |
| Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm |
| Connection 2 | |
| Connection in acc. with standard | based on IEC 60603-13 |
| Connection method | Yokogawa, KS compatible |
| Number of connections | 1 |
| Number of positions | 50 |
| Tightening torque | 0.5 Nm (Screw connection) |
| Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm |
| Cable | |
| Length | 15 m |
| 50X0.14 [PVC] | |
| UL AWM Style | 2464/1061 |
| Number of positions | 50 |
| Shielded | yes |
| Cable type | 50X0.14 [PVC] |
| Conductor type | Assembled shielded round cable |
| Conductor structure signal line | 7x 0.16 mm |
| AWG signal line | 26 |
| Conductor cross section | 50x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| External cable diameter | 11.00 mm ±0.3 mm |
| Outer sheath, material | Semi-rigid PVC |
| External sheath, color | gray |
| Conductor material | Tin-plated Cu litz wires |
| Cable resistance | ≤ 145 Ω/km (at 20 °C) |
| Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Smallest bending radius, fixed installation | 114 mm |
| Smallest bending radius, movable installation | 205 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 18x outside diameter) |
| Halogen-free | no |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| VDE 0842, Part 332-1-2 (raw cable) | |
| IEC 60332-3-22 (raw cable) | |
| UL VW-1 | |
| CSA FT-1 | |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| -10 °C ... 70 °C (flexible installation) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| UKCA | |
| Certificate | UKCA-compliant |
| Mounting position | any |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |