PHOENIX CONTACT FLK 20/2FLK14/EZ-DR/500/KONFEK FLK 20/2FLK14/EZ-DR/500/KONFEK 2902707 PHOENIX CONTACT Cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FLK 20/2FLK14/EZ-DR/500/KONFEK 2902707 PHOENIX CONTACT Cable

FLK 20/2FLK14/EZ-DR/500/KONFEK

2902707

PHOENIX CONTACT

1 Pcs.

Cable Ready-made round cable; Connection 1: Female IDC/FLK connection (1x 20-poles); Connection 2: Female IDC/FLK connection (2x 14-pole); Cable length: 5 m Round cable set; connection 1: IDC/FLK socket strip (1x 20-position); connection 2: IDC/FLK socket strip (2x 14-position); cable length: 5 m

Cables > PLC connection cable
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact FLK 20/2FLK14/EZ-DR/500/KONFEK is a system cable utilized to interface automation controllers with modular I/O hardware blocks. Factory-built cabling solutions maintain dependable electrical connections in complex process and factory automation applications.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: System cable
  • Data management status Article revision: 03
  • Ambient conditions Degree of protection: IP00
  • Degree of protection (Installation location): ≥ IP54 (Installation location)
  • Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
  • Ambient temperature (storage/transport): -40 °C ... 80 °C
  • Altitude: ≤ 2000 m
  • Operating voltage (AC): ≤ 30 V AC
  • Operating voltage (DC): ≤ 60 V DC
  • Nominal operating mode: 100% operating factor
  • Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
  • Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
  • Supported controller EMERSON DeltaV Suitable I/O card: VE4001S2T2B5
  • Supported controller SIEMENS ET 200SP Suitable base unit: 6ES7193-6BP00-0BA0
  • Suitable I/O module: 6ES7131-6BH01-0BA0 (Base Units A0/A1)
  • Cable length: 5 m

More info

▲
Technical data

Product properties
Product typeSystem cable
Data management status
Article revision03

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP00
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient temperature (operation)-40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

Electrical properties
Operating voltage (AC)≤ 30 V AC
Operating voltage (DC)≤ 60 V DC
Nominal operating mode100% operating factor
Current (Per path, 50°C)≤ 1 A (Uncoiled, see derating)
Current (Per path, 70°C)≤ 0.6 A (Uncoiled, see derating)
Supported controller EMERSON DeltaV
Suitable I/O cardVE4001S2T2B5
VE4002S1T2B6
Supported controller SIEMENS ET 200SP
Suitable base unit6ES7193-6BP00-0BA0
6ES7193-6BP00-2BA0
6ES7193-6BP00-0BA1
6ES7193-6BP00-0DA0
6ES7193-6BP00-2DA0
6ES7193-6BP00-0DA1
Suitable I/O module6ES7131-6BH01-0BA0 (Base Units A0/A1)
6ES7131-6BH01-2BA0 (Base Units A0/A1)
6ES7132-6BH01-0BA0 (Base Units A0/A1)
6ES7132-6BH01-2BA0 (Base Units A0/A1)

Cable/line
Cable length5 m
20X0.14 [PVC]
UL AWM Style2464/1061
Number of positions20
Shieldedno
Cable type20X0.14 [PVC]
Conductor typeRound cable set
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section20x 0.14 mm²
Wire diameter incl. insulation1 mm ±0.03 mm
External cable diameter7.60 mm ±0.4 mm
Outer sheath, materialSemi-rigid PVC
External sheath, colorgray
Conductor materialTin-plated Cu litz wires
Cable resistance≤ 145 Ω/km (20 °C)
Insulation resistance≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation64 mm
Smallest bending radius, movable installation120 mm
Dynamic load capacity (bending)Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter)
Halogen-freeno
Flame resistanceIEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1
Resistance to oilcan withstand occasional splashes (raw cable)
Cable typeSplitting cable for two modules
Color code
blackIDC/FLK20 (1) = IDC/FLK14-1 (1)
brownIDC/FLK20 (2) = IDC/FLK14-1 (2)
redIDC/FLK20 (3) = IDC/FLK14-1 (3)
orangeIDC/FLK20 (4) = IDC/FLK14-1 (4)
yellowIDC/FLK20 (5) = IDC/FLK14-1 (5)
greenIDC/FLK20 (6) = IDC/FLK14-1 (6)
blueIDC/FLK20 (7) = IDC/FLK14-1 (7)
violetIDC/FLK20 (8) = IDC/FLK14-1 (8)
grayIDC/FLK20 (9) = IDC/FLK14-2 (1)
whiteIDC/FLK20 (10) = IDC/FLK14-2 (2)
white-blackIDC/FLK20 (11) = IDC/FLK14-2 (3)
white-brownIDC/FLK20 (12) = IDC/FLK14-2 (4)
white-redIDC/FLK20 (13) = IDC/FLK14-2 (5)
white-orangeIDC/FLK20 (14) = IDC/FLK14-2 (6)
white-yellowIDC/FLK20 (15) = IDC/FLK14-2 (7)
white-greenIDC/FLK20 (16) = IDC/FLK14-2 (8)
white-blueIDC/FLK20 (17) = IDC/FLK14-2 (9)
white-violetIDC/FLK20 (18) = IDC/FLK14-2 (10)
white-grayIDC/FLK20 (19) = IDC/FLK14-1 (9)
brown-blackIDC/FLK20 (20) = IDC/FLK14-1 (10)

Connection data
Connection 1
Connection in acc. with standardbased on IEC 60603-13
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions20
Insertion/withdrawal cycles> 50
Pitch2.54 mm
Connection 2
Connection in acc. with standardbased on IEC 60603-13
Connection methodIDC/FLK socket strip
Number of connections2
Number of positions14
Insertion/withdrawal cycles> 50
Pitch2.54 mm

Notes
Notes on operationFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.