Narrow Ethernet switch devices are compact networking components utilized in space-constrained control cabinets to interconnect local automation equipment. The Phoenix Contact FL SWITCH 1005N model delivers straightforward unmanaged connectivity for general machine networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Ethernet (EF003535): Yes
- Number of other ports (EF007643): 5
- Manageable (EF004912): No
- Degree of protection (IP) (EF005474): IP30
- Height (EF000040): 123.081014 mm
- Width (EF000008): 22.5 mm
- Depth (EF000049): 90.035944 mm
More info
▲Key Commercial Data
| Orderkey | 1085039 |
|---|---|
| Packing unit | 1 pc |
| Weight per Piece (excluding packing) | 220.000 g |
| Country of origin | TW (Taiwan) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Degree of protection | IP30 |
|---|---|
| Ambient temperature (operation) | -10 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Air pressure (operation) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
| Air pressure (storage/transport) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
Interfaces
| Interface | Ethernet (RJ45) |
|---|---|
| No. of ports | 5 (RJ45 ports) |
| Note on the connection method | Auto negotiation and autocrossing |
| Transmission physics | Ethernet in RJ45 twisted pair |
| Transmission speed | 10/100 Mbps |
| Transmission length | 100 m (per segment) |
| Signal LEDs | Data receive, link status |
Function
| Basic functions | Unmanaged switch / auto negotiation, complies with IEEE 802.3, store and forward switching mode |
|---|---|
| Additional functions | Autonegotiation |
| MAC address table | 2k |
| PROFINET conformance class | Conformance-Class A |
| Status and diagnostic indicators | LEDs: US, link and activity per port |
Network expansion parameters
| Cascading depth | Network, linear, and star structure: any |
|---|---|
| Maximum conductor length (twisted pair) | 100 m |
Supply voltage
| Supply voltage | 24 V DC |
|---|---|
| 24 V AC (50/60 Hz) | |
| Residual ripple | 3.6 VPP(within the permitted voltage range) |
| Supply voltage range | 9 V DC ... 32 V DC |
| 18 V AC ... 30 V AC (50/60 Hz) | |
| Typical current consumption | 19 mA |
| Max. current consumption | 110 mA |
General
| Mounting type | DIN rail |
|---|---|
| Type AX | Stand-alone |
| Net weight | 170 g |
| Housing material | Plastic |
| MTTF | 167.2 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%) |
| 1627 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) | |
| 1526 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
Connection data
| Connection method | Push-in spring connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | EN 61000-6-2 EN 61000-4-8 (electromagnetic fields) Criterion A |
| Conducted noise emission | EN 61000-6-2 Class A |
| Immunity to surge | EN 61000-6-2 EN 61000-4-5 (surge) Criterion B |
| Immunity to burst | EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A |
| Immunity to EF | EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A |
| Immunity to ESD | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Immunity to conducted interference | EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A |
| Type of test | Free fall in accordance with EN 61131-2 |
| Noise emission | EN 61000-6-4:2007 + A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Vibration (storage/transport) | 5g, 150 Hz, in acc. with IEC 60068-2-6 |
| Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
| Shock (operation) | 30g (EN 60068-2-27) |
| UL, USA/Canada | UL 61010-1, UL 61010-2-201, UL 62368-1 Class I, Div. 2, Groups A, B, C, D, T4 Class I, Zone 2, Group IIC, T4 |