View larger
FL NAT 2208 2702882 PHOENIX CONTACT Managed NAT Switch 2000, 8 RJ45 ports 10/100 Mbps, degree of protection:..
FL NAT 2208
2702882
PHOENIX CONTACT
1 Pcs.
Automation > Network switch
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Managed NAT Switch 2000, 8 RJ45 ports 10/100 Mbps, degree of protection:.. is utilized in industrial automation networks to provide managed switching alongside Network Address Translation (NAT) for connecting disparate machine subnets. The Phoenix Contact FL NAT 2208 helps standardize IP addresses and secure communication between factory floor devices.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Ethernet (EF003535): Yes
- Number of other ports (EF007643): 8
- Manageable (EF004912): Yes
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 130.592254 mm
- Width (EF000008): 45 mm
- Depth (EF000049): 125.1 mm
More info
▲Key Commercial Data
| Orderkey | 2702882 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 328 (C-6-2019) |
| GTIN | 4055626384825 |
| Weight per Piece (excluding packing) | 400.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Air pressure (operation) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
| Air pressure (storage/transport) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
Interfaces
| Interface | Ethernet (RJ45) |
|---|---|
| No. of ports | 8 (RJ45 ports) |
| Note on the connection method | Auto negotiation and autocrossing |
| Transmission physics | Copper |
| Transmission speed | 10/100 Mbps |
| Transmission length | 100 m (per segment) |
| Signal LEDs | Data receive, link status |
Function
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 |
|---|---|
| Management | Web-based management (HTTP/HTTPS) |
| SNMPv1/v2/v3 | |
| Command-line interface (Telnet, SSH) | |
| Diagnostic functions | RMON History |
| LLDP (Link Layer Discovery Protocol) | |
| SNMP-Traps | |
| N:1-Portmirroring | |
| ACD (Address Conflict Detection) | |
| SysLog | |
| CRC-Surveillance | |
| Filter functions | Quality of Service (8 priority classes) |
| Port-Priorisierung | |
| VLAN (up to 32 VLANs) | |
| IGMP Snooping/Querier (v1/v2) | |
| Auto-Query-Port | |
| Extended Multicast Filtering | |
| NAT functions | 1:1-NAT |
| Virtual-NAT | |
| IP-Masquerading | |
| Port forwarding | |
| Redundancy | MRP (Media Redundancy Protocol) |
| RSTP (Rapid Spanning Tree Protocol) | |
| FRD (Fast Ring Detection) | |
| Large Tree Support | |
| LACP (Link Aggregation Control Protocol) | |
| MAC address table | 8k |
| IP parameterization | DHCP-Client |
| DHCP Option 82 (Relay Agent) | |
| DHCP server (pool-based, port-based) | |
| BootP | |
| PROFINET device function | PROFINET device |
| PROFINET conformance class | Conformance-Class B |
| Time synchronization | SNTP (Simple Network Time Protocol) |
| Status and diagnostic indicators | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
| Signal contact control voltage | typ. 24 V DC |
Network expansion parameters
| Cascading depth | Network, linear, and star structure: any |
|---|---|
| Maximum conductor length (twisted pair) | 100 m |
Supply voltage
| Supply voltage | 24 V DC (redundant) |
|---|---|
| Residual ripple | 3.6 VPP(within the permitted voltage range) |
| Supply voltage range | 9 V DC ... 57 V DC |
| Typical current consumption | 185 mA (at US= 24 V DC and 25 °C ambient temperature) |
| Max. current consumption | 1.3 A (US= Min, Tamb= Max, DOI= Max) |
| Current consumption | 190 mA |
General
| Mounting type | DIN rail |
|---|---|
| Type AX | Book type |
| Net weight | 260 g |
| Housing material | Polycarbonate fiber reinforced |
| Note | Support by phone or on-site (fee is charged) |
| Special properties | 1:1-NAT, Virtual NAT, IP-Masquerading |
| MTTF | 494.02 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| 235.18 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
| 29.73 Years (SN 29500 standard, temperature 70 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
Connection data
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.08 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.08 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 28 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 7 mm |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | EN 61000-6-2 EN 61000-6-4 (interference) Class A |
| Conducted noise emission | EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A |
| Immunity to surge | EN 61000-6-2 EN 61000-4-5 (surge) Criterion B |
| Immunity to burst | EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A |
| Immunity to EF | EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A |
| Immunity to ESD | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Immunity to conducted interference | EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A |
| Type of test | Free fall in accordance with EN 61131-2 |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Vibration (storage/transport) | 5g, 150 Hz, in acc. with IEC 60068-2-6 |
| Free from substances that could impair the application of coating | Yes |
| Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
| Shock (operation) | 30g (EN 60068-2-27) |
| ATEX | II 3 G Ex ec IIC T4 Gc |
| IECEx | Ex ec IIC T4 Gc |
| UL, USA | UL 60079-0, Ed.6 / UL 60079-7, Ed.5 |
| UL, USA/Canada | Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 |
| UL, Canada | CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 |
| Noxious gas test | ISA S71.04.2013 G3 Harsh Group A |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |
Classifications
eCl@ss
| eCl@ss 10.0.1 | 19170401 |
|---|---|
| eCl@ss 5.0 | 19030100 |
| eCl@ss 5.1 | 19030100 |
| eCl@ss 6.0 | 19170100 |
| eCl@ss 7.0 | 19170106 |
| eCl@ss 8.0 | 19170106 |
| eCl@ss 9.0 | 19170106 |