Request QuoteProduct Overview
Incorporating spring-clamp technology, the Phoenix Contact FKC 2,5/ 4-ST-5,08 BD:X16 printed-circuit board connector ensures secure, tool-optimized conductor termination. Such modular interconnection products are widely used in control engineering to link external field devices to circuit boards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contact type (EF001587): Bus
- Number of poles (EF001391): 4
- Number of plug-in contact rows (EF006935): 1
- Modular spacing contacts (EF007326): 5.08 mm
- Modular spacing connections (EF006827): 5.08 mm
- Rated current In (EF008250): 12 A
- Rated voltage (EF000228): 320 V
- Rated surge voltage (EF002993): 4 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 2
- Connectable conductor cross section solid-core (EF007337): 0.2 mm²
- Type of electric connection (EF003961): Spring clamp connection
- Connectable cable type (EF006816): Tubular cable
- Material of contact surface (EF004020): Tin
- Material contact (EF007544): Copper
- Material insulation body (EF007543): Polyamide (PA)
More info
▲General
| Range of articles | FKC 2,5/..-ST |
|---|---|
| Number of positions | 4 |
| Connection method | Push-in spring connection |
| Rated surge voltage (III/3) | 4 kV |
| Rated surge voltage (III/2) | 4 kV |
| Rated surge voltage (II/2) | 4 kV |
| Rated voltage (III/3) | 320 V |
| Rated voltage (III/2) | 320 V |
| Rated voltage (II/2) | 630 V |
| Connection in acc. with standard | EN-VDE |
| Nominal current IN | 12 A |
| Nominal cross section | 2.5 mm² |
| Internal cylindrical gage | A2 |
| Stripping length | 10 mm |
Connection data
| Conductor cross section solid min. | 0.2 mm² |
|---|---|
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 1 mm² |
| Minimum AWG according to UL/CUL | 26 |
| Maximum AWG according to UL/CUL | 12 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |