View larger
FKC 2,5/ 3-ST-5,08 GY BD:NZ308 1701583 PHOENIX CONTACT Plug
FKC 2,5/ 3-ST-5,08 GY BD:NZ308
1701583
PHOENIX CONTACT
1000 Pcs.
Cables > Cable connector
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Streamlining internal wiring tasks, this Phoenix Contact FKC 2,5/ 3-ST-5,08 GY BD:NZ308 plug uses efficient spring-clamp technology for rapid conductor termination. Such terminal connectors find widespread application in dynamic industrial automation systems, control panels, and modular electronics. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contact type (EF001587): Bus
- Number of poles (EF001391): 3
- Number of plug-in contact rows (EF006935): 1
- Modular spacing contacts (EF007326): 5.08 mm
- Modular spacing connections (EF006827): 5.08 mm
- Rated current In (EF008250): 12 A
- Rated voltage (EF000228): 320 V
- Rated surge voltage (EF002993): 4 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 2
- Connectable conductor cross section solid-core (EF007337): 0.2 mm²
- Type of electric connection (EF003961): Spring clamp connection
- Connectable cable type (EF006816): Tubular cable
- Material of contact surface (EF004020): Tin
- Material contact (EF007544): Copper
- Material insulation body (EF007543): Polyamide (PA)
More info
▲General
| Range of articles | FKC 2,5/..-ST |
|---|---|
| Number of positions | 3 |
| Connection method | Push-in spring connection |
| Rated surge voltage (III/3) | 4 kV |
| Rated surge voltage (III/2) | 4 kV |
| Rated surge voltage (II/2) | 4 kV |
| Rated voltage (III/3) | 320 V |
| Rated voltage (III/2) | 320 V |
| Rated voltage (II/2) | 630 V |
| Connection in acc. with standard | EN-VDE |
| Nominal current IN | 12 A |
| Nominal cross section | 2.5 mm² |
| Internal cylindrical gage | A2 |
| Stripping length | 10 mm |
Connection data
| Conductor cross section solid min. | 0.2 mm² |
|---|---|
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 1.5 mm² |
| Minimum AWG according to UL/CUL | 26 |
| Maximum AWG according to UL/CUL | 12 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |