PHOENIX CONTACT SAC-4P-M12MS/0,6-800/M12FR-3LW SAC-4P-M12MS/0,6-800/M12FR-3LW 1569265 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-M12MS/0,6-800/M12FR-3LW 1569265 PHOENIX CONTACT Sensor/actuator cable

SAC-4P-M12MS/0,6-800/M12FR-3LW

1569265

PHOENIX CONTACT

25 Pcs.

Sensor/actuator cable

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Sensor/actuator cable SAC-4P-M12MS/0,6-800/M12FR-3LW from Phoenix Contact integrates status indication directly into the connection line for immediate diagnostic feedback. These indicator cables are widely utilized on automated machinery to display operational states right at the sensor node. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Orderkey: 1569265
  • Packing unit: 1
  • GTIN: 4046356555340
  • Custom tariff number: 85444290
  • Length of cable: 0.6 m
  • Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
  • Degree of protection: IP65
  • Rated current at 40°C: 4 A
  • Rated voltage: 250 V
  • Number of positions: 4
  • Insulation resistance: ≥ 100 MΩ
  • Coding: A - standard
  • Status display: 3 LEDs
  • Overvoltage category: II
  • Degree of pollution: 3
  • Insertion/withdrawal cycles: ≥ 100

More info

▲

Key Commercial Data

Orderkey 1569265
Packing unit 1
GTIN4046356555340
Custom tariff number85444290

Dimensions

Length of cable0.6 m

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
Degree of protectionIP65
IP67
IP68

General

Rated current at 40°C4 A
Rated voltage250 V
24 V DC
Number of positions4
Insulation resistance≥ 100 MΩ
CodingA - standard
Status display3 LEDs
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Torque0.4 Nm (M12 connector)

Material

Flammability rating according to UL 94HB
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR

Standards and Regulations

Flammability rating according to UL 94HB

Cable

NoteDue to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable typeGray, highly flexible PUR
Cable type (abbreviation)800
Cable abbreviationLi12YYTPE-HF
UL AWM style20233
Conductor cross section4x 0.34 mm² (Signal line)
AWG signal line22
Conductor structure signal line42x 0.10 mm
Core diameter including insulation1.3 mm ±0.05 mm (Signal line)
Wire colorsbrown, white, blue, black
Overall twist4 wires, twisted
External sheath, colorgray RAL 7001
External cable diameter D4.8 mm ±0.2 mm
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation7.5 x D
Number of bending cycles10000000
Minimum bending radius, drag chain applications7,5 x D
Traversing path5 m
Traversing rate3.3 m/s
Acceleration5 m/s²
Number of bending cycles15000000
Bending radius50 mm
Traversing path0.9 m
Traversing rate5 m/s
Acceleration30 m/s²
Torsion force± 360 °/m (1 000 000 torsion cycles)
Cable weight33.5 kg/km
Outer sheath, materialPUR
Material conductor insulationPES
Conductor materialBare Cu litz wires
Insulation resistance≥ 20 MΩ*km
Conductor resistanceapprox. 53 Ω/km
Nominal voltage, cable300 V
Test voltage, cable2000 V
Special propertiesCable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Free from silicone and cadmium
Free of substances which would hinder coating with paint or varnish
Flame resistanceaccording to IEC 60332-1-2
according to UL 758/1581 VW-1
according to UL 758/1581 FT1
Halogen-freein accordance with DIN VDE 0472 part 815
Resistance to oilAccording to HD 22.10
in accordance with DIN EN 60811-404 (external sheath)
Other resistanceHighly resistant to acids, alkaline solutions and solvents
Silicone-free
Ambient temperature (operation)-40 °C ... 90 °C (cable, fixed installation)
-30 °C ... 90 °C (cable, flexible installation)
to 120 °C (for 3000 h)

Classifications