View larger
FK-MCP 1,5/ 3-STF-3,5 BD:1-3 1714360 PHOENIX CONTACT PCB connector, nominal current: 8 A, rated voltage (III..
FK-MCP 1,5/ 3-STF-3,5 BD:1-3
1714360
PHOENIX CONTACT
1000 Pcs.
Cables > Cable connector
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed with a spring clamp connection system, the Phoenix Contact FK-MCP 1,5/ 3-STF-3,5 BD:1-3 (1714360) printed-circuit board connector enables quick wiring for compact control hardware. Plug-in terminal blocks help streamline assembly processes by providing reliable, vibration-resistant interfaces for printed circuit boards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contact type (EF001587): Bus
- Number of plug-in contact rows (EF006935): 1
- Modular spacing contacts (EF007326): 3.5 mm
- Modular spacing connections (EF006827): 3.5 mm
- Rated current In (EF008250): 8 A
- Rated voltage (EF000228): 160 V
- Rated surge voltage (EF002993): 2.5 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 2
- Connectable conductor cross section solid-core (EF007337): 0.14 mm²
- Type of electric connection (EF003961): Spring clamp connection
- Connectable cable type (EF006816): Tubular cable
- Material of contact surface (EF004020): Tin
- Material contact (EF007544): Copper
- Material insulation body (EF007543): Polyamide (PA)
- Housing colour (EF000136): Green
More info
▲Item properties
| Brief article description | PCB connector |
|---|---|
| Plug-in system | MINI COMBICON |
| Type of contact | Female connector |
| Range of articles | FK-MCP 1,5/..-STF |
| Pitch | 3.5 mm |
| Number of positions | 3 |
| Connection method | Push-in spring connection |
| Number of levels | 1 |
Connection capacity
| Connection method | Push-in spring connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG / kcmil | 26 ... 16 |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 0.5 mm² |
| Cylindrical gauge a x b / diameter | 2.4 mm x 1.5 mm / - |
| Stripping length | 9 mm |
Specifications for ferrules
| Recommended crimping pliers | 1212034 CRIMPFOX 6 |
|---|---|
| Ferrules without insulating collar, according to DIN 46228‑1 | Cross section: 0.25 mm²; Length: 7 mm |
| Cross section: 0.34 mm²; Length: 7 mm | |
| Cross section: 0.5 mm²; Length: 8 mm ... 10 mm | |
| Cross section: 0.75 mm²; Length: 8 mm ... 10 mm | |
| Cross section: 1 mm²; Length: 8 mm ... 10 mm | |
| Cross section: 1.5 mm²; Length: 10 mm | |
| Recommended crimping pliers | 1212034 CRIMPFOX 6 |
| Ferrules with insulating collar, according to DIN 46228‑4 | Cross section: 0.14 mm²; Length: 8 mm |
| Cross section: 0.25 mm²; Length: 8 mm | |
| Cross section: 0.34 mm²; Length: 8 mm | |
| Cross section: 0.5 mm²; Length: 8 mm ... 10 mm | |
| Cross section: 0.75 mm²; Length: 10 mm |
Material data - contact
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
|---|---|
| Contact material | Cu alloy |
| Surface characteristics | hot-dip tin-plated |
| Metal surface terminal point (top layer) | Tin (4 - 8 µm Sn) |
| Metal surface contact area (top layer) | Tin (4 - 8 µm Sn) |
Material data - housing
| Insulating material | PA |
|---|---|
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | V0 |
| Glow wire flammability index GWFI according to EN 60695-2-12 | 850 |
| Glow wire ignition temperature GWIT according to EN 60695-2-13 | 775 |
| Temperature for the ball pressure test according to EN 60695-10-2 | 125 °C |
Material data – actuating element
| Insulating material | POM |
|---|---|
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | HB |
Dimensions for the product
| Dimensional drawing | |
|---|---|
| Length [ l ] | 20.8 mm |
| Width [ w ] | 20.8 mm |
| Height [ h ] | 12.4 mm |
| Pitch | 3.5 mm |
| Height (without solder pin) | 12.4 mm |
| Dimension a | 7 mm |
Packaging information
| Type of packaging | packed in cardboard |
|---|---|
| Pieces per package | 50 |
| Denomination packing units | Pcs. |
Ambient conditions
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 100 °C (dependent on the derating curve) |
Termination and connection method
| Conductor connection test | The stripped-off ends of the largest conductor can be completely inserted in the opening of the terminal point without using excessive force. |
|---|---|
| Test result | Test passed |
| Test – repeated connection and release | IEC 60999-1:1999-11 |
| Test passed | |
| Test for conductor damage and slackening | IEC 60999-1:1999-11 |
| Test passed |
Pull-out test
| Pull-out test | IEC 60999-1:1999-11 |
|---|---|
| Test passed | |
| Conductor cross section / conductor type / tensile force | 0.14 mm² / solid / > 10 N |
| 0.14 mm² / flexible / > 10 N | |
| 1.5 mm² / solid / > 40 N | |
| 1.5 mm² / flexible / > 40 N |
Mechanical tests according to standard
| Visual examination | Test passed IEC 60512-1-1:2002-02 |
|---|---|
| Dimensional test | Test passed IEC 60512-1-2:2002-02 |
| Resistance of marking | Test passed IEC 60068-2-70:1995-12 |
| Result | Test passed |
| Specification | IEC 60512-13-2:2006-02 |
| No. of cycles | 25 |
| Insertion strength per pos. approx. | 7 N |
| Withdraw strength per pos. approx. | 5 N |
| Polarization and coding | Test passed IEC 60512-13-5:2006-02 |
| Result | Test passed |
| Specification | IEC 60512-15-1:2008-05 |
| Test force per pos. | 26 N |
Air clearances and creepage distances
| Clearances and creepage distances | IEC 60664-1:2007-04 |
|---|---|
| Specification | IEC 60664-1:2007-04 |
| Rated insulation voltage (III/3) | 160 V |
| Rated insulation voltage (III/2) | 160 V |
| Rated insulation voltage (II/2) | 320 V |
| Rated surge voltage (III/3) | 2.5 kV |
| Rated surge voltage (III/2) | 2.5 kV |
| Rated surge voltage (II/2) | 2.5 kV |
| Minimum clearance - inhomogeneous field (III/3) | 1.5 mm |
| Minimum clearance - inhomogeneous field (III/2) | 1.5 mm |
| Minimum clearance - inhomogeneous field (II/2) | 1.5 mm |
| Minimum creepage distance value (III/3) | 2 mm |
| Minimum creepage distance value (III/2) | 1.5 mm |
| Minimum creepage distance value (II/2) | 1.6 mm |
Temperature cycles
| Specification | IEC 60999-1:1999-11 |
|---|---|
| Test current (minimum cross section) | 4 A DC |
| Test current (maximum cross section) | 8 A DC |
| Temperature cycles | 192 |
Mechanical tests (A)
| Insertion strength per pos. approx. | 7 N |
|---|---|
| Withdraw strength per pos. approx. | 5 N |
| Polarization when inserted requirement >20 N | Test passed |
| Contact holder in insert requirements >20 N | Test passed |
Durability tests (B)
| Specification | IEC 60512-5:1992-08 |
|---|---|
| Contact resistance R1 | 2 mΩ |
| Insertion/withdrawal cycles | 25 |
| Contact resistance R2 | 2.2 mΩ |
| Impulse withstand voltage at sea level | 2.95 kV |
| Power-frequency withstand voltage | 1.39 kV |
| Insulation resistance, neighboring positions | 1012Ω |
Climatic tests (D)
| Specification | ISO 6988:1985-02 |
|---|---|
| Cold stress | -40 °C/2 h |
| Thermal stress | 100 °C/168 h |
| Corrosive stress | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Impulse withstand voltage at sea level | 2.95 kV |
| Power-frequency withstand voltage | 1.39 kV |
Environmental and durability tests (E)
| Specification | IEC 61984:2008-10 |
|---|---|
| Result, degree of protection, IP code | Finger safety with IP20 test finger |