PHOENIX CONTACT FK-MCP 1,5/ 3-ST-3,5BKLCBUBD+Q FK-MCP 1,5/ 3-ST-3,5BKLCBUBD+Q 1067628 PHOENIX CONTACT Connector for printed circuit board, number of poles:.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FK-MCP 1,5/ 3-ST-3,5BKLCBUBD+Q 1067628 PHOENIX CONTACT Connector for printed circuit board, number of poles:..

FK-MCP 1,5/ 3-ST-3,5BKLCBUBD+Q

1067628

PHOENIX CONTACT

1000 Pcs.

Connector for printed circuit board, number of poles: 3, pitch: 3.5 mm, color: black Connector for printed circuit board, nominal section: 1.5 mm², color: black, nominal current: 8 A, nominal voltage (III/2): 160 V, contact surface: Tin, contact type: Female, number of rows: 1, number of poles: 3, family of articles: FK-MCP 1.5/.. -ST, pitch: 3.5mm, connection type: Push-in spring connection, conductor/printed circuit board connection direction: 0°, plug-in system: COMBICON MC 1.5, lock: without, fixing type: without, packaging type: boxed PCB connector, nominal cross-section: 1.5 mm2, colour: black, rated current: 8 A, dimensioning voltage (III/2): 160 V, contact surface: Sn, contact connection type: Female, number of rows: 1, number of poles: 3, product series: FK-MCP 1.5/.. -ST, pitch: 3.5 mm, connection type: Push-in spring connection, conductor/board connection direction: 0 °, plug system: COMBICON MC 1.5, locking: none, fastening type: none, packaging type: packed in carton

Cables > Cable connector
PCB Connectors (PCC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact FK-MCP 1,5/ 3-ST-3,5BKLCBUBD+Q connector for printed circuit board applications provides quick spring-cage termination for low-voltage signaling networks. Compact pluggable connectors are essential in instrumentation and automation devices for maintaining secure, vibration-resistant connections. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product Type: Printed circuit board connector
  • Product Family: FK-MCP 1.5/.. -ST
  • Product Line: COMBICON Connectors S
  • Number of poles: 3
  • Step: 3.5 mm
  • Number of rows: 1
  • Data maintenance status Article review: 00
  • Rated Current I N: 8 A
  • Rated voltage U N: 160 V
  • Mass Resistivity: 2 mΩ
  • Sizing voltage (III/3): 160 V
  • Sizing impulse voltage (III/3): 2.5 kV
  • Sizing voltage (III/2): 160 V
  • Sizing Impulse Voltage (III/2): 2.5 kV
  • Sizing voltage (II/2): 320 V
  • Sizing Impulse Voltage (II/2): 2.5 kV

More info

▲

Product TypePrinted circuit board connector
Product FamilyFK-MCP 1.5/.. -ST
Product LineCOMBICON Connectors S
Number of poles3
Step3.5 mm
Number of rows1
Data maintenance status
Article review00

Rated Current IN8 A
Rated voltage UN160 V
Mass Resistivity2 mΩ
Sizing voltage (III/3)160 V
Sizing impulse voltage (III/3)2.5 kV
Sizing voltage (III/2)160 V
Sizing Impulse Voltage (III/2)2.5 kV
Sizing voltage (II/2)320 V
Sizing Impulse Voltage (II/2)2.5 kV

Connection technology
typeStandard
Connector systemCOMBICON MC 1.5
Nominal cross-section1.5 mm²
Contact Connection Typefemale
Blockage
Clamping Typeabsent
Fixing flangeabsent
Conductor connection
LinkPush-in spring connection
Conductor/board connection direction0 °
Rigid conductor cross-section0.14 mm² ... 1.5 mm²
Flexible conductor cross-section0.14 mm² ... 1.5 mm²
Conductor cross-section AWG26 ... 16
Flexible conductor cross-section with cable lug without plastic collar0.25 mm² ... 1.5 mm²
Flexible conductor cross-section with mounted lug and plastic collar0.25 mm² ... 0.5 mm²
Buffer Gauge a x b / diameter2.4 mm x 1.5 mm / -
Length of the section to be stripped9 mm
Indications for ferrules without isolation collar
Recommended crimping tool1212034 CRIMPFOX 6
cable lug without insulating collar, in accordance with DIN 46228-1Cross-section: 0.25 mm²; Length: 7 mm
Cross-section: 0.34 mm²; Length: 7 mm
Cross-section: 0.5 mm²; Length: 8 mm 10 mm
Cross-section: 0.75 mm²; Length: 8 mm 10 mm
Cross-section: 1 mm²; Length: 8 mm 10 mm
Cross-section: 1.5 mm²; Length: 10 mm
Indications for ferrules with isolation collar
Recommended crimping tool1212034 CRIMPFOX 6
cable lug with insulating collar, in accordance with DIN 46228-4Cross-section: 0.14 mm²; Length: 8 mm
Cross-section: 0.25 mm²; Length: 8 mm
Cross-section: 0.34 mm²; Length: 8 mm
Cross-section: 0.5 mm²; Length: 8 mm 10 mm

Material information - contacts
noteComplies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201
Contact MaterialCu Alloy
Surface FinishHot-dip galvanizing
Metal Surface, Connection Point (Surface Layer)Tin (4 - 8 μm Sn)
Metal surface contact zone (surface layer)Tin (4 - 8 μm Sn)
Material information - case
Color (Case)Black (9005)
Insulation materialPA
Insulation Material GroupThe
CTI according to IEC 60112600
Combustibility class according to UL 94V0
Flammability index of GWFI filament according to EN 60695-2-12850
GWIT filament ignition temperature according to EN 60695-2-13775
Brinell hardness test temperature according to EN 60695-10-2125 °C
Material data - drive element
Colour (Drive Element)Blue (5015)
Insulation materialPOM
Insulation Material GroupThe
CTI according to IEC 60112600
Combustibility class according to UL 94HB

Dimensioned Drawing
Step3.5 mm
Width [w]11.4 mm
Height [h]12.4 mm
Length [l]21 mm

Conductor connection
Test SpecificationDIN EN 60999-1 (VDE 0609-1):2000-12
ResultTest passed
Conductor Integrity and Stability Test
Test SpecificationDIN EN 60999-1 (VDE 0609-1):2000-12
ResultTest passed
Repeated connection and disconnection
Test SpecificationDIN EN 60999-1 (VDE 0609-1):2000-12
ResultTest passed
Tensile test
Test SpecificationDIN EN 60999-1 (VDE 0609-1):2000-12
Conductor cross-section/conductor type/tensile force nominal value/actual value0.14 mm² / rigid / > 10 N
0.14 mm² / flexible / > 10 N
1.5 mm² / rigid / > 40 N
1.5 mm² / flexible / > 40 N
Insertion/tensile force
Test SpecificationDIN EN 60512-13-2:2006-11
ResultTest passed
Number of cycles25
Insertion force per pole approx.7 N
Tensile force per pole approx.5 N
Resistance of lettering
Test SpecificationDIN EN 60068-2-70:1996-07
ResultTest passed
Polarization and encoding
Test SpecificationDIN EN 60512-13-5:2006-11
ResultTest passed
Visual inspection
Test SpecificationDIN EN 60512-1-1:2003-01
ResultTest passed
Dimensional control
Test SpecificationDIN EN 60512-1-2:2003-01
ResultTest passed

Vibration test
Test SpecificationDIN EN 60068-2-6 (VDE 0468-2-6):2008-10
Frequency10 - 150 - 10 Hz
Sweep Speed1 octave/min
Amplitude0.35 mm (10 Hz ... 60.1 Hz)
Acceleration5g (60.1 Hz ... 150 Hz)
Test duration per axle2.5 h
Test DirectionsX, Y, and Z axis
Electrical life control
Test SpecificationDIN IEC 60512-5:1994-05
Vertical impulse tension above sea level2.95 kV
Mass Resistivity R12 mΩ
Mass Resistivity R22.2 mΩ
Manoeuvring cycles25
Climate control
Test SpecificationDIN EN ISO 6988:1997-03
Stress due to corrosion0.2 dm3KNOW2on 300 dm3/40 °C/1 cycle
Stress due to the effect of heat100 °C/168 h
Fixed AC voltage1.39 kV
Environmental conditions
Ambient temperature (operating)-40 °C ... 100 °C (depending on derating curve)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Relative humidity (transport and storage)30 % ... 70 %
Ambient temperature (mounting)-5 °C ... 100 °C

Thermal Test Control Group C
Test SpecificationDIN EN 60512-5-1:2003-01
Number of poles tested20
Insulation Resistance
Test SpecificationDIN EN 60512-3-1:2003-01
Insulation Resistance Between Contiguous Poles1012Ω
Temperature Cycling
Test SpecificationDIN EN 60999-1 (VDE 0609-1):2000-12
ResultTest passed
Creepage and Creepage Distances
Test SpecificationDIN EN 60664-1 (VDE 0110-1):2008-01
Insulation Material GroupThe
Resistance to surface currents (DIN EN 60112 (VDE 0303-11))CTI 600
Rated insulation voltage (III/3)160 V
Rated impulse voltage (III/3)2.5 kV
Minimum clearance value - inhomogeneous range (III/3)1.5 mm
Minimum creepage value (III/3)2 mm
Rated Isolation Voltage (III/2)160 V
Rated impulse voltage (III/2)2.5 kV
Minimum creepage value - inhomogeneous range (III/2)1.5 mm
Minimum creepage value (III/2)1.5 mm
Rated Isolation Voltage (II/2)320 V
Rated Impulse Voltage (II/2)2.5 kV
Minimum creepage value - inhomogeneous range (II/2)1.5 mm
Minimum creepage value (II/2)1.6 mm

PackagingPacked in carton

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.