View larger
UKH 240 3010217 PHOENIX CONTACT High-current terminal block
UKH 240
3010217
PHOENIX CONTACT
1 Pcs.
Automation > Feed-through terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
High-current terminal block part number UKH 240 by Phoenix Contact is engineered to securely connect massive power cables in heavy industrial machinery, switchgear, and energy distribution systems. These robust components handle extreme electrical loads safely while maintaining reliable contact pressure under heavy vibration. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: High current terminal block
- Number of connections: 2
- Number of rows: 1
- Potentials: 1
- Data management status Article revision: 11
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Rated surge voltage: 8 kV
- Maximum power dissipation for nominal condition: 13.78 W
- Number of connections per level: 2
- Nominal cross section: 240 mm²
- Level 1 above 1 below 1 Screw thread: M10
- Note: Screws with hexagonal socket
- Tightening torque: 25 ... 30 Nm
- Stripping length: 40 mm
- Internal cylindrical gage: B15
More info
▲| General | |
| Note | For a reliable contact of multi stranded conductors it is recommended to untwist multi stranded conductors. |
| Product type | High current terminal block |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data management status | |
| Article revision | 11 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 8 kV |
| Maximum power dissipation for nominal condition | 13.78 W |
| Number of connections per level | 2 |
| Nominal cross section | 240 mm² |
| Level 1 above 1 below 1 | |
| Screw thread | M10 |
| Note | Screws with hexagonal socket |
| Tightening torque | 25 ... 30 Nm |
| Stripping length | 40 mm |
| Internal cylindrical gage | B15 |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section rigid | 70 mm² ... 240 mm² |
| Cross section AWG | 3/0 ... 250 kcmil (converted acc. to IEC) |
| Conductor cross section flexible | 70 mm² ... 240 mm² |
| Conductor cross section, flexible [AWG] | 3/0 ... 350 kcmil (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 70 mm² ... 185 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 70 mm² ... 185 mm² |
| Cross-section with insertion bridge, rigid | 240 mm² |
| Cross-section with insertion bridge, flexible | 185 mm² |
| 2 conductors with same cross section, solid | 35 mm² ... 95 mm² |
| 2 conductors with same cross section, flexible | 50 mm² ... 95 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 35 mm² ... 50 mm² |
| Nominal current | 415 A |
| Maximum load current | 415 A (with 240 mm² conductor cross section) |
| Nominal voltage | 1000 V |
| Note | Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area. |
| Nominal cross section | 240 mm² |
| Rated data (ATEX/IECEx) | |
| Identification | II 2 GD Ex eb IIC Gb |
| Operating temperature range | -60 °C ... 110 °C |
| Ex-certified accessories | 1201947 VDE-ISS 8 |
| 1201659 E/AL-NS 32 | |
| 1201662 E/AL-NS 35 | |
| List of bridges | Insertion bridge / EB 2-36/UKH / 0201401 |
| Insertion bridge / EB 3-36/UKH / 0201414 | |
| Bridge data | 270 A / 240 mm² |
| Ex temperature increase | 40 K (389 A/240 mm²) |
| Rated voltage | 1100 V |
| at bridging with insertion bridge | 690 V |
| Rated insulation voltage | 1000 V |
| output | (Permanent) |
| Ex level General | |
| Rated current | 350 A |
| Maximum load current | 350 A |
| Contact resistance | 0.03 mΩ |
| Ex connection data General | |
| Stripping length | 40 mm |
| Torque range | 25 Nm ... 30 Nm |
| Nominal cross section | 240 mm² |
| Rated cross section AWG | 500 kcmil |
| Connection capacity rigid | 70 mm² ... 240 mm² |
| Connection capacity AWG | 2/0 ... 500 kcmil |
| Connection capacity flexible | 70 mm² ... 240 mm² |
| Connection capacity AWG | 2/0 ... 500 kcmil |
| 2 conductors with same cross section, solid | 35 mm² ... 95 mm² |
| 2 conductors with the same cross-section AWG rigid | 2 ... 3/0 |
| 2 conductors with same cross section, stranded | 50 mm² ... 95 mm² |
| 2 conductors with the same cross-section AWG flexible | 1/0 ... 3/0 |
| Dimensional drawing | |
| Width | 36 mm |
| Height | 100 mm |
| Depth | 123.6 mm |
| Depth on NS 32 | 129 mm |
| Depth on NS 35/15 | 131.5 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Surge voltage test | |
| Result | Test passed |
| Short-time withstand current 240 mm² | 28.8 kA |
| Result | Test passed |
| Power-frequency withstand voltage | |
| Test voltage setpoint | 2.2 kV |
| Result | Test passed |
| Mechanical data | |
| Open side panel | No |
| Mechanical strength | |
| Result | Test passed |
| Attachment on the carrier | |
| DIN rail/fixing support | NS 32/NS 35 |
| Result | Test passed |
| Test for conductor damage and slackening | |
| Rotation speed | 10 (+/- 2) rpm |
| Revolutions | 135 |
| Conductor cross section/weight | 70 mm²/10.4 kg |
| 240 mm²/20.0 kg | |
| Result | Test passed |
| Needle-flame test | |
| Time of exposure | 30 s |
| Result | Test passed |
| Oscillation/broadband noise | |
| Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Spectrum | Service life test category 2, bogie-mounted |
| Frequency | f1= 5 Hz to f2= 250 Hz |
| ASD level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test directions | X-, Y- and Z-axis |
| Result | Test passed |
| Shocks | |
| Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Pulse shape | Half-sine |
| Acceleration | 5g |
| Shock duration | 30 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Result | Test passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection in acc. with standard | IEC 60947-7-1 |
| Mounting type | NS 35/15 |
| NS 32 |