View larger
ST 16 BU 3036152 PHOENIX CONTACT Feed-through terminal block
ST 16 BU
3036152
PHOENIX CONTACT
50 Pcs.
Automation > Feed-through terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Feed-through terminal block (Phoenix Contact ST 16 BU) provides a standard modular connection point for passing control and power signals through DIN rail assemblies. They ensure solid wire retention and dependable electrical continuity in automated machinery and switchgear. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Feed-through terminal block
- Number of connections: 2
- Number of rows: 1
- Potentials: 1
- Data management status Article revision: 16
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Rated surge voltage: 8 kV
- Maximum power dissipation for nominal condition: 2.43 W
- Number of connections per level: 2
- Nominal cross section: 16 mm²
- Stripping length: 18 mm
- Internal cylindrical gage: A7
- Connection in acc. with standard: IEC 60947-7-1
- Conductor cross section rigid: 0.2 mm² ... 25 mm²
- Cross section AWG: 24 ... 4 (converted acc. to IEC)
More info
▲| Product type | Feed-through terminal block |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data management status | |
| Article revision | 16 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 8 kV |
| Maximum power dissipation for nominal condition | 2.43 W |
| Number of connections per level | 2 |
| Nominal cross section | 16 mm² |
| Stripping length | 18 mm |
| Internal cylindrical gage | A7 |
| B6 | |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section rigid | 0.2 mm² ... 25 mm² |
| Cross section AWG | 24 ... 4 (converted acc. to IEC) |
| Conductor cross section flexible | 0.2 mm² ... 16 mm² |
| Conductor cross section, flexible [AWG] | 24 ... 6 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 16 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 16 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 1.5 mm² ... 4 mm² |
| Nominal current | 76 A |
| Maximum load current | 90 A (with 25 mm² conductor cross section) |
| Nominal voltage | 1000 V |
| Nominal cross section | 16 mm² |
| Rated data (ATEX/IECEx) | |
| Identification | II 2 GD Ex eb IIC Gb |
| Operating temperature range | -60 °C ... 110 °C |
| Ex-certified accessories | 3036657 D-ST 16 |
| 1206612 SZF 3-1,0X5,5 | |
| 3022276 CLIPFIX 35-5 | |
| 3022218 CLIPFIX 35 | |
| List of bridges | Plug-in bridge / FBS 2-12 / 3005950 |
| Bridge data | 60 A / 16 mm² |
| Ex temperature increase | 40 K (71.3 A / 16 mm²) |
| Rated voltage | 550 V |
| for bridging with bridge | 550 V |
| Rated insulation voltage | 500 V |
| output | (Permanent) |
| Ex level General | |
| Rated current | 64.5 A |
| Maximum load current | 81.5 A |
| Contact resistance | 0.34 mΩ |
| Ex connection data General | |
| Nominal cross section | 16 mm² |
| Rated cross section AWG | 6 |
| Connection capacity rigid | 1.5 mm² ... 25 mm² |
| Connection capacity AWG | 16 ... 4 |
| Connection capacity flexible | 1.5 mm² ... 16 mm² |
| Connection capacity AWG | 16 ... 6 |
| Width | 12.2 mm |
| End cover width | 2.2 mm |
| Height | 80 mm |
| Depth on NS 35/7,5 | 51.5 mm |
| Depth on NS 35/15 | 59 mm |
| Color | blue (RAL 5015) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Mechanical data | |
| Open side panel | Yes |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection in acc. with standard | IEC 60947-7-1 |
| Mounting type | NS 35/7,5 |
| NS 35/15 |