View larger
HDFK 95-F-VP/Z 0717076 PHOENIX CONTACT Panel feed-through terminal block, Connection method: Screw connectio..
HDFK 95-F-VP/Z
0717076
PHOENIX CONTACT
10 Pcs.
Automation > Panel feed-through terminal block
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An HDFK 95-F-VP/Z PHOENIX CONTACT Panel feed-through terminal block delivers secure, high-capacity wire routing across protective panel walls in demanding electrical installations. Industrial power distribution networks rely on these robust terminal blocks to handle substantial currents safely. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Number of levels: 1
- Number of connections: 2
- Nominal cross section: 95 mm²
- Color: gray
- Insulating material: PA
- Flammability rating according to UL 94: V0
- Maximum load current: 232 A
- Rated surge voltage: 8 kV
- Pollution degree: 3
- Overvoltage category: III
- Insulating material group: I
- Connection in acc. with standard: IEC 60947-7-1
- Nominal current I N: 232 A
- Maximum load current: 232 A
- Nominal voltage U N: 630 V (metal panels 2.5 mm ... 5 mm)
- Number of positions: 1
More info
▲General
| Number of levels | 1 |
|---|---|
| Number of connections | 2 |
| Nominal cross section | 95 mm² |
| Color | gray |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
General
| Maximum load current | 232 A |
|---|---|
| Rated surge voltage | 8 kV |
| Pollution degree | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Connection in acc. with standard | IEC 60947-7-1 |
| Nominal current IN | 232 A |
| Maximum load current | 232 A |
| Nominal voltage UN | 630 V (metal panels 2.5 mm ... 5 mm) |
| 500 V (metal panels 5 mm ... 6 mm) | |
| Number of positions | 1 |
Dimensions
| Width | 25 mm |
|---|---|
| Length | 91.5 mm |
| Plate thickness | 1 mm ... 6 mm |
Connection data
| Note | Terminal sleeve |
|---|---|
| Connection side | Outside |
| Connection method | Screw connection |
| Conductor cross section solid min. | 35 mm² |
| Conductor cross section solid max. | 95 mm² |
| Conductor cross section flexible min. | 35 mm² |
| Conductor cross section flexible max. | 95 mm² |
| Conductor cross section AWG min. | 4 |
| Conductor cross section AWG max. | 3/0 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 30 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 95 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 30 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 95 mm² |
| 2 conductors with same cross section, solid min. | 25 mm² |
| 2 conductors with same cross section, solid max. | 35 mm² |
| 2 conductors with same cross section, stranded min. | 25 mm² |
| 2 conductors with same cross section, stranded max. | 35 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. | 16 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. | 35 mm² |
| Stripping length | 27 mm |
| Internal cylindrical gage | B12 |
| Screw thread | M8 |
| Tightening torque, min | 15 Nm |
| Tightening torque max | 20 Nm |
| Connection side | Inside |
| Connection method | Cable lug connection |
| Screw thread | M10 |
| Tightening torque, min | 15 Nm |
| Tightening torque max | 20 Nm |