View larger
HDFK 25-PE 0707785 PHOENIX CONTACT PE panel panel feed-through terminal block, Connection method: Screw conn..
HDFK 25-PE
0707785
PHOENIX CONTACT
50 Pcs.
Automation > Panel feed-through terminal block
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing a protective ground path, this Phoenix Contact HDFK 25-PE PE panel panel feed-through terminal block, Connection method: Screw conn.. secures grounding conductors directly to panel walls. Protective conductor blocks are critical safety elements in electrical installations, ensuring reliable fault current dissipation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of levels: 1
- Number of connections: 2
- Nominal cross section: 25 mm²
- Color: green-yellow
- Insulating material: PA
- Flammability rating according to UL 94: V0
- Rated surge voltage: 6 kV
- Pollution degree: 3
- Overvoltage category: III
- Insulating material group: I
- Connection in acc. with standard: IEC 60947-7-2
- Nominal current I N: 101 A
- Maximum load current: 125 A
- Nominal voltage U N: 500 V
- Open side panel: nein
- Number of positions: 1
More info
▲General
| Number of levels | 1 |
|---|---|
| Number of connections | 2 |
| Nominal cross section | 25 mm² |
| Color | green-yellow |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
General
| Rated surge voltage | 6 kV |
|---|---|
| Pollution degree | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Connection in acc. with standard | IEC 60947-7-2 |
| Nominal current IN | 101 A |
| Maximum load current | 125 A |
| Nominal voltage UN | 500 V |
| Open side panel | nein |
| Number of positions | 1 |
Dimensions
| Width | 15.1 mm |
|---|
Connection data
| Note | Terminal sleeve |
|---|---|
| Connection side | Level 1 ext. 1 |
| Connection method | Screw connection |
| Note | Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area. |
| Conductor cross section solid min. | 6 mm² |
| Conductor cross section solid max. | 35 mm² |
| Conductor cross section flexible min. | 10 mm² |
| Conductor cross section flexible max. | 25 mm² |
| Conductor cross section AWG min. | 10 |
| Conductor cross section AWG max. | 2 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 4 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 25 mm² |
| 2 conductors with same cross section, solid min. | 2.5 mm² |
| 2 conductors with same cross section, solid max. | 10 mm² |
| 2 conductors with same cross section, stranded min. | 4 mm² |
| 2 conductors with same cross section, stranded max. | 10 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. | 2.5 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. | 10 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 2.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 10 mm² |
| Stripping length | 19 mm |
| Internal cylindrical gage | B8 |
| Screw thread | M5 |
| Tightening torque, min | 4 Nm |
| Tightening torque max | 4.5 Nm |
| Conductor cross section solid min. | 6 mm² |
| Conductor cross section solid max. | 35 mm² |
| Conductor cross section flexible min. | 10 mm² |
| Conductor cross section flexible max. | 25 mm² |
| Conductor cross section AWG min. | 10 |
| Conductor cross section AWG max. | 2 |