Phoenix Contact monitoring module provides system diagnostics and fault signal relaying within modular signal conditioning and automation architectures. Monitoring modules protect industrial processes by detecting threshold violations and communicating status changes to control systems.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Accessory (EF013236): Yes
- Spare part (EF013237): No
More info
▲Key Commercial Data
| Orderkey | 2904508 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 104 (C-5-2017) |
| GTIN | 4046356857390 |
| Weight per Piece (excluding packing) | 96.300 g |
| Custom tariff number | 85437090 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Input data
| Description of the input | Voltage input for redundancy monitoring |
|---|---|
| Number of inputs | 1 |
| Voltage input signal | 9.9 V DC ... 30 V DC |
Switching output
| Output name | Switching output |
|---|---|
| Maximum switching voltage | 30 V DC |
| Max. switching current | 50 mA |
Power supply
| Supply voltage range | 12 V DC ... 24 V DC -20 % ... +25 % (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
|---|---|
| Max. current consumption | < 16 mA (at 24 V DC) |
| Power consumption | < 410 mW (at 24 V DC) |
Connection data
| Connection method | Push-in connection |
|---|---|
| Single conductor/terminal point, solid, with ferrule, min. | 0.14 mm² |
| Single conductor/terminal point, solid, with ferrule, max. | 2.5 mm² |
| Single conductor/terminal point, solid, without ferrule, min. | 0.14 mm² |
| Single conductor/terminal point, solid, without ferrule, max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Min. AWG conductor cross section, flexible | 24 |
| Max. AWG conductor cross section, flexible | 12 |
| Stripping length | 10 mm |
General
| Maximum temperature coefficient | < 0.01 %/K |
|---|---|
| Test voltage | 1500 V AC (50 Hz, 1 min.) |
| Status display | Yellow LED (switching output) |
| Electrical isolation | Basic insulation according to EN 61010 |
| Overvoltage category | II |
| Degree of pollution | 2 |
| Rated insulation voltage | 50 V AC/DC (effective) |
| Test voltage input/output | 1.5 kV AC (50 Hz, 1 min.) |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Housing material | PBT |
| Mounting position | any |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA IIC T4 Gc X |
| UL, USA/Canada | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T6 | |
| Class I, Zone 2, Group IIC T6 | |
| Certificate of classification | DNV GL 14445-15HH |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC directive |
|---|---|
| Noise emission | EN 61000-6-4 |
| Standards/regulations | EN 61000-4-2 |
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
| EN 61000-4-4 | |
| EN 61000-4-5 | |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Electrical isolation | Basic insulation according to EN 61010 |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA IIC T4 Gc X |
| UL, USA/Canada | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T6 | |
| Class I, Zone 2, Group IIC T6 | |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |