View larger
Images are for illustrative purposes only. Please refer to data sheet for details
FA MCR-D-TUI-UI-2REL-UP 2907064 PHOENIX CONTACT Digital display
FA MCR-D-TUI-UI-2REL-UP
2907064
PHOENIX CONTACT
1 Pcs.
Digital display
Boxed multifunctional process indicator for electrical panel components for monitoring and displaying analog measured values. Universal inputs allow connection of current, voltage, RTDs, and thermocouples. 2 switched contact relay outputs and 1 analog output.
Automation > Accessories/spare parts for HVAC sensors
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Panel-mounted digital display modules like the FA MCR-D-TUI-UI-2REL-UP 2907064 PHOENIX CONTACT Digital display by Phoenix Contact provide reliable numeric readout capabilities for standard measurement and control loops. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2907064
- Packing unit: 1 pc
- Catalog page: Page 180 (C-5-2017)
- GTIN: 4055626204666
- Weight per Piece (excluding packing): 539.800 g
- Custom tariff number: 90303330
- Country of origin: DE (Germany)
- Width: 96 mm
- Height: 48 mm
- Depth: 151.8 mm
- Ambient temperature (operation): -20 °C ... 60 °C
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Maximum altitude: < 2000 m (Above sea level)
- Degree of protection: IP65 from the front
- Description of the input: Universal input
- Number of inputs: 1
More info
▲Key Commercial Data
| Orderkey | 2907064 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 180 (C-5-2017) |
| GTIN | 4055626204666 |
| Weight per Piece (excluding packing) | 539.800 g |
| Custom tariff number | 90303330 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | < 2000 m (Above sea level) |
| Degree of protection | IP65 from the front |
Input data
| Description of the input | Universal input |
|---|---|
| Number of inputs | 1 |
| Current input signal | 0 mA ... 20 mA +10 % |
| 4 mA ... 20 mA +10 % | |
| Max. input current | < 150 mA |
| Input signal | Current |
| Input resistance current input | 10 Ω |
| Transmitter supply voltage | > 16 V (22 mA) |
| Transmitter supply voltage range | 22.8 V ... 27.6 V (No-load) |
| Transmitter supply current | < 30 mA (Short-circuit and overload protection) |
| Available input sources | Resistance thermometers |
| Sensor types (RTD) that can be used | Pt, Ni, Cu sensors |
| Connection technology | 2, 3, 4-wire |
| Description of the input | Universal input |
| Voltage input signal | 0 V ... 10 V |
| 2 V ... 10 V | |
| 0 V ... 5 V | |
| 0 V ... 1 V | |
| 1 V ... 5 V | |
| -1 V ... 1 V | |
| -10 V ... 10 V | |
| -30 V ... 30 V | |
| -100 mV ... 100 mV | |
| max. input voltage | ± 35 V (≥ 1 V) |
| Input signal | Voltage |
| Input resistance of voltage input | > 1 MΩ |
| Available input sources | Thermocouples |
| Sensor types that can be used (TC) | J, K, T, N, B, S, R, U. L, C, D |
Output data
| Output name | Current output |
|---|---|
| Number of outputs | 1 |
| Configurable/programmable | Yes |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| Max. output current | < 22 mA |
| Load/output load current output | ≤ 500 Ω (22 mA) |
| Ripple | < 10 mVPP(500 Ω) |
| D/A resolution | 13 bit |
| Output name | Voltage output |
| Voltage output signal | 0 V ... 10 V |
| 2 V ... 10 V | |
| 0 V ... 5 V | |
| 1 V ... 5 V | |
| Max. output voltage | < 11 V |
| Ripple | < 10 mVPP(1000 Ω) |
| D/A resolution | 13 bit |
Switching output
| Output name | Relay output |
|---|---|
| Contact type | 2 PDT |
| Minimum switching voltage | 12 V |
| Maximum switching voltage | 30 V DC (3 A) |
| 230 V AC (3 A) | |
| Min. switching current | 10 mA |
| Output name | Transistor output, active |
| Output description | Open collector output |
| Number of outputs | 1 |
| Contact type | Transistor |
| Maximum switching voltage | 28 V |
| Max. switching current | 3 A |
| 200 mA |
Power supply
| Supply voltage range | 24 V AC/DC ... 230 V AC/DC (-20 % ... +10 %, 50 Hz ... 60 Hz) |
|---|---|
| Max. current consumption | 30 mA |
| Power consumption | ≤ 6.9 W |
General
| Maximum transmission error | ± 0.05 % () |
|---|---|
| Test voltage | 2500 V |
| Protection class | I |
| Overvoltage category | II |
| Degree of pollution | 2 |
| Test voltage input/output | 500 V |
| Test voltage input/power supply | 2500 V |
| Test voltage output/power supply | 2500 V |
| Test voltage input/power supply | 2.5 kV |
| Noise emission | IEC 61326, class A |
| Noise immunity | IEC 61326 / NAMUR NE 21 |
| Color | light gray RAL 7035 |
| Housing material | PC-GF10 |
| Mounting position | Max. viewing angle range +/- 45° from the centre line of the display in every direction |
| Conformance | CE-compliant |
| UL, USA/Canada | UL 61010 Recognized |
| CSA | CSA GP |
| GL | GL EMC 1 C |
Standards and Regulations
| Noise emission | IEC 61326, class A |
|---|---|
| Noise immunity | IEC 61326 / NAMUR NE 21 |
| Conformance | CE-compliant |
| UL, USA/Canada | UL 61010 Recognized |
| CSA | CSA GP |
| GL | GL EMC 1 C |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |