View larger
FL MEM PLUG/MRM 2891275 PHOENIX CONTACT Configuration memory
FL MEM PLUG/MRM
2891275
PHOENIX CONTACT
1 Pcs.
Automation > PLC memory card
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Configuration memory hardware stores device parameters, network settings, and control logic, allowing for rapid device replacement without manual reprogramming. Panel builders and maintenance personnel deploy these memory units to streamline maintenance workflows and minimize industrial control system downtime. Pricing, availability and lead time are confirmed per enquiry through an RFQ for this Phoenix Contact FL MEM PLUG/MRM part.
- Memory size (EF002997): 64 kByte
More info
▲Key Commercial Data
| Orderkey | 2891275 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 423 (C-6-2017) |
| GTIN | 4046356165433 |
| Weight per Piece (excluding packing) | 19.000 g |
| Custom tariff number | 84717098 |
| Country of origin | DE (Germany) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | 0 °C ... 55 °C (non-condensing) |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Conformity with EMC directives
| Developed in acc. with standard | IEC 61000-6.2 |
|---|---|
| Test standard | IEC 61000-4-2 (ESD) |
| Test result | Criterion B |
| Test standard | IEC 61000-4-3 (immunity to radiated interference) |
| Test result | Criterion A |
| Test standard | IEC 61000-4-4 (burst) |
| Test result | Criterion A |
| Test standard | IEC 61000-4-5 (surge) |
| Test result | Criterion A |
| Test standard | IEC 61000-4-6 (immunity to conducted interference) |
| Test result | Criterion A |
| Test standard | IEC 61000-4-8 (immunity to magnetic fields) |
| Test result | Criterion A |
| Test standard | EN 55022 (emitted interference) |
| Test result | Criterion A |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC |
|---|---|
| Noise emission | EN 61000-6-3/-4 |
| Noise immunity | EN 61000-6-2:2005 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |