View larger
ETD-BL-2T-I-230-PT 2907714 PHOENIX CONTACT Timer relay
ETD-BL-2T-I-230-PT
2907714
PHOENIX CONTACT
1 Pcs.
Automation > Timer relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact ETD-BL-2T-I-230-PT is a DIN rail mountable timer relay engineered to provide consistent timing control within industrial machinery and control cabinets. Time relays are fundamental for managing automated sequences, process timing, and equipment safety routines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Timer relay
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Article revision: 00
- Insulation characteristics Insulation: Basic insulation
- Overvoltage category: III
- Pollution degree: 2
- Service life electrical: approx. 2x 10 5 cycles at ohmic load, 1000 VA
- Nominal frequency: 48 Hz ... 63 Hz
- Nominal power consumption: 2.5 VA (1 W)
- Test voltage relay winding/relay contact: 4 kV
- Rated insulation voltage: 300 V
- Nominal power consumption: 2.5 VA (1 W)
- Input voltage range: 24 V AC/DC ... 240 V AC/DC -10 % ... +15 %
- Temperature coefficient, typical: ≤ 0.01 %/K
- Recovery time: 500 ms
More info
▲| Product type | Timer relay |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Article revision | 00 |
| Insulation characteristics | |
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
| Service life electrical | approx. 2x 105cycles at ohmic load, 1000 VA |
| Nominal frequency | 48 Hz ... 63 Hz |
| Nominal power consumption | 2.5 VA (1 W) |
| Test voltage relay winding/relay contact | 4 kV |
| Rated insulation voltage | 300 V |
| Nominal power consumption | 2.5 VA (1 W) |
| Input voltage range | 24 V AC/DC ... 240 V AC/DC -10 % ... +15 % |
| Temperature coefficient, typical | ≤ 0.01 %/K |
| Recovery time | 500 ms |
| Function | lp: Switched-mode beginning with the pause |
| li: Switched-mode beginning with the pulse | |
| Setting range time | 50 ms ... 100 h (7 time end ranges) |
| Basic accuracy | ± 1 % (of scale end value) |
| Setting accuracy | ≤ 5 % (of scale end value) |
| Repeat accuracy | ≤ 0.5 % ±5 ms |
| Control | |
| Connection name | Non-floating, terminals A1-B1 |
| Control pulse length | ≥ 50 ms (DC) |
| ≥ 100 ms (AC) | |
| Switching | |
| Contact switching type | 1 floating changeover contact |
| Maximum switching voltage | 250 V AC (in acc. with IEC 60664-1) |
| Interrupting rating (ohmic load) max. | 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing) |
| 1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing) | |
| Output fuse | 5 A (fast-blow) |
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
| Status display | Green LED (POWER) |
| Yellow LED (relay active) |
| Width | 17.5 mm |
| Height | 89.5 mm |
| Depth | 65.5 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Ambient conditions | |
| Degree of protection (Housing) | IP40 (Housing) |
| Degree of protection (Connection terminal blocks) | IP20 (Connection terminal blocks) |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| -25 °C ... 40 °C (corresponds to UL 508) | |
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Permissible humidity (operation) | 15 % ... 85 % |
| CE | |
| Certificate | CE-compliant |
| UKCA | |
| Certificate | UKCA-compliant |
| Electromagnetic compatibility | Conformance with EMC directive |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Noise immunity | EN 61000-6-2 |
| Noise emission | EN 61000-6-4 |
| Standards/regulations | EN 50178 |
| Mounting type | DIN rail mounting |
| Assembly note | on standard DIN rail NS 35 in accordance with EN 60715 |
| Mounting position | any |