D-ST 16 3036657 PHOENIX CONTACT End cover
D-ST 16
3036657
PHOENIX CONTACT
50 Pcs.
Automation > Endplate and partition plate for terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as an essential barrier, the D-ST 16 3036657 PHOENIX CONTACT End cover safely encloses the open side of modular terminal block assemblies. Components like this protect exposed metal contacts from dust, moisture, and accidental touch while completing the electrical insulation profile of a DIN rail setup. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: End cover
- Data management status Article revision: 03
- Ambient temperature (storage/transport): -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
- Ambient temperature (assembly): -5 °C ... 70 °C
- Ambient temperature (actuation): -5 °C ... 70 °C
- Permissible humidity (operation): 20 % ... 90 %
- Permissible humidity (storage/transport): 30 % ... 70 %
- Color: gray (RAL 7042)
- Material: PA
- Flammability rating according to UL 94: V0
- Static insulating material application in cold: -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
- Surface flammability NFPA 130 (ASTM E 162): passed
More info
▲| Product type | End cover |
| Data management status | |
| Article revision | 03 |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Color | gray (RAL 7042) |
| Material | PA |
| Flammability rating according to UL 94 | V0 |
| Static insulating material application in cold | -60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Width | 2.2 mm |
| Height | 80 mm |
| Depth | 51.1 mm |