Product Overview

Phoenix Contact D-PTME 4 end cover provides proper insulation and mechanical closure for the exposed open sides of modular terminal blocks. These protective covers ensure safety and environmental protection at the terminal strip ends in industrial control panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Orderkey: 3212167
  • Packing unit: 10 pc
  • Minimum order quantity: 10 pc
  • Catalog page: Page 99 (C-1-2017)
  • GTIN: 4046356512749
  • Weight per Piece (excluding packing): 3.820 g
  • Custom tariff number: 85389099
  • Country of origin: PL (Poland)
  • Color: gray
  • Material: PA
  • Flammability rating according to UL 94: V0
  • Width: 2.2 mm
  • End cover width: 2.2 mm
  • Length: 70.6 mm
  • Height: 39.7 mm
  • Static insulating material application in cold: -60 °C

More info

▲

Key Commercial Data

Orderkey3212167
Packing unit10 pc
Minimum order quantity10 pc
Catalog pagePage 99 (C-1-2017)
GTIN4046356512749
Weight per Piece (excluding packing)3.820 g
Custom tariff number85389099
Country of originPL (Poland)

General

Colorgray
MaterialPA
Flammability rating according to UL 94V0

Dimensions

Width2.2 mm
End cover width2.2 mm
Length70.6 mm
Height39.7 mm

General

Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Standards and Regulations

Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet