PHOENIX CONTACT D-PTC 2,5-MT D-PTC 2,5-MT 3270097 PHOENIX CONTACT End cover View larger
Images are for illustrative purposes only. Please refer to data sheet for details

D-PTC 2,5-MT 3270097 PHOENIX CONTACT End cover

D-PTC 2,5-MT

3270097

PHOENIX CONTACT

50 Pcs.

End cover End cap, length: 56 mm, width: 2.2 mm, height: 29 mm, colour: grey End cover, depth: 29 mm, width: 2.2 mm, height: 56 mm, color: gray

Automation > Endplate and partition plate for terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Protective barriers like the D-PTC 2,5-MT 3270097 PHOENIX CONTACT End cover are installed on DIN rail terminals to close off exposed conductive parts and safeguard internal circuitry from environmental exposure. They maintain required clearance distances at the margins of terminal block groups.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: End cover
  • Data management status Article revision: 01
  • Ambient temperature (storage/transport): -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
  • Ambient temperature (assembly): -5 °C ... 70 °C
  • Ambient temperature (actuation): -5 °C ... 70 °C
  • Permissible humidity (operation): 20 % ... 90 %
  • Permissible humidity (storage/transport): 30 % ... 70 %
  • Color: gray (RAL 7042)
  • Material: PA
  • Flammability rating according to UL 94: V0
  • Static insulating material application in cold: -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
  • Calorimetric heat release NFPA 130 (ASTM E 1354): 28 MJ/kg

More info

▲
Technical data

Product properties
Product typeEnd cover
Data management status
Article revision01

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Material specifications
Colorgray (RAL 7042)
MaterialPA
Flammability rating according to UL 94V0
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Dimensions
Width2.2 mm
End cover width2.2 mm
Height56 mm
Depth29 mm
Depth on NS 35/7,536.5 mm
Depth on NS 35/1544 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.