PHOENIX CONTACT EMG 17-REL/KSR-24/21/SO54 EMG 17-REL/KSR- 24/21/SO54 2946366 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EMG 17-REL/KSR- 24/21/SO54 2946366 PHOENIX CONTACT Relay Module

EMG 17-REL/KSR-24/21/SO54

2946366

PHOENIX CONTACT

10 Pcs.

Relay Module Relay module, with soldered mini-switching relay, contact (AgNi): Medium to high powers, 1 switched contact, input voltage 24 V AC/DC Relay module, with soldered-in miniature switching relay, contact (AgNi): Medium to large loads, 1 PDT, input voltage 24 V AC/DC

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The EMG 17-REL/KSR- 24/21/SO54 2946366 PHOENIX CONTACT Relay Module serves as a crucial interface component in electrical control cabinets, enabling reliable signal conversion and galvanic isolation between controllers and plant equipment. Engineers employ such modules to protect automation hardware, manage auxiliary loads, and ensure dependable signal transmission in demanding industrial environments.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area
  • Product type: Relay Module
  • Mechanical service life: 3x 10 7 cycles
  • Data management status Date of last data management: 02.05.2024
  • Article revision: 13
  • Overvoltage category: III
  • Pollution degree: 2
  • Maximum power dissipation for nominal condition: 0.5 W
  • Rated surge voltage: 6 kV (1.2/50 μs)
  • Coil side Nominal input voltage U N: 24 V AC/DC
  • Input voltage range: 21.6 V AC/DC ... 26.4 V AC/DC (20 °C)
  • Typical input current at U N: 17.5 mA
  • Typical response time: 8 ms
  • Typical release time: 10 ms
  • Protective circuit: Bridge rectifier; Bridge rectifier
  • Operating voltage display: Yellow LED

More info

▲
Technical data

Notes
Utilization restriction
EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties
Product typeRelay Module
Mechanical service life3x 107cycles
Data management status
Date of last data management02.05.2024
Article revision13
Insulation characteristics: Air clearances and creepage distances, input/output
InsulationReinforced insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties
Maximum power dissipation for nominal condition0.5 W
Air clearances and creepage distances, input/output
Rated insulation voltage250 V
Rated surge voltage6 kV (1.2/50 μs)

Input data
Coil side
Nominal input voltage UN24 V AC/DC
Input voltage range21.6 V AC/DC ... 26.4 V AC/DC (20 °C)
Typical input current at UN17.5 mA
Typical response time8 ms
Typical release time10 ms
Protective circuitBridge rectifier; Bridge rectifier
Operating voltage displayYellow LED

Output data
Switching
Contact switching typeSingle contact, 1 changeover contact
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Limiting continuous current6 A
Maximum inrush current15 A (max. 4 seconds up to a duty ratio of 10%)
Interrupting rating (ohmic load) max.144 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
1500 VA (for 250 V AC)

Connection data
Coil side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Contact side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Dimensions
Width17.5 mm
Height75 mm
Depth62.5 mm

Material specifications
Colorgreen (RAL 6021)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient temperature (operation)-20 °C ... 50 °C
Altitude≤ 2000 m

Standards and regulations
Air clearances and creepage distances, input/output
Standards/regulationsDIN EN 50178: 1998-04

Mounting
Mounting typeDIN rail mounting
Mounting positionany

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.