EM-CPS-PS/3AC/24DC/5 1064922 PHOENIX CONTACT Primary-switched power supply unit, TRIO POWER, Snap-on connect..
EM-CPS-PS/3AC/24DC/5
1064922
PHOENIX CONTACT
1 Pcs.
Automation > DC-power supply
Power Supplies (PS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact EM-CPS-PS/3AC/24DC/5 primary-switched power supply unit provides regulated direct current for sensitive automation technology and control cabinets. Power supplies of this type ensure stable voltage distribution across complex industrial networks, PLCs, and auxiliary equipment. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1064922
- Packing unit: 1
- Catalog page: Page 262 (C-4-2019)
- GTIN: 4055626725222
- Custom tariff number: 85044030
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Width: 36 mm
- Height: 160 mm
- Depth: 159 mm
- Degree of protection: IP20
- Ambient temperature (operation): -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Max. permissible relative humidity (operation): ≤ 95 % (at 25 °C, non-condensing)
- Climatic class: 3K3 (in acc. with EN 60721)
- Degree of pollution: 2
- Installation height: ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
More info
▲Key Commercial Data
| Orderkey | 1064922 |
|---|---|
| Packing unit | 1 |
| Catalog page | Page 262 (C-4-2019) |
| GTIN | 4055626725222 |
| Custom tariff number | 85044030 |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Degree of pollution | 2 |
| Installation height | ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) |
Input data
| Nominal input voltage range | 3x 400 V AC ... 500 V AC |
|---|---|
| 2x 400 V AC ... 500 V AC | |
| Input voltage range | 3x 400 V AC ... 500 V AC -20 % ....+15 % |
| 2x 400 V AC ... 500 V AC -10 % ... +15 % | |
| AC frequency range | 50 Hz ... 60 Hz |
| Discharge current to PE | < 0.25 mA |
| Current consumption | 3x 0.4 A (400 V AC) |
| 3x 0.3 A (500 V AC) | |
| 2x 0.6 A (400 V AC) | |
| 2x 0.5 A (500 V AC) | |
| Nominal power consumption | 243.6 VA |
| Inrush current | ≤ 22 A (typical) |
| Mains buffering time | typ. 20 ms (400 V AC) |
| typ. 20 ms (500 V AC) | |
| Input fuse | 3.15 A (internal (device protection), slow-blow) |
| Recommended breaker for input protection | 6 A ... 16 A (AC: Characteristics B, C, D, K) |
| Power factor (cos phi) | 0.55 |
| Type of protection | Transient surge protection |
| Protective circuit/component | Varistor |
Output data
| Nominal output voltage | 24 V DC ±1 % |
|---|---|
| Setting range of the output voltage (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| Nominal output current (IN) | 5 A |
| Dynamic Boost (IDyn.Boost) | 7.5 A (5 s) |
| Derating | > 60 °C ... 70 °C (2.5%/K) |
| Connection in parallel | Yes, for redundancy and increased capacity |
| Connection in series | yes |
| Protection against overvoltage at the output (OVP) | ≤ 30 V DC |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
| < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | ≤ 20 mVPP |
| Output power | 120 W |
| Typical response time | < 1 s |
| Maximum power dissipation in no-load condition | < 1 W (400 V AC) |
| Power loss nominal load max. | < 12 W (480 V AC) |
General
| Net weight | 0.7 kg |
|---|---|
| Efficiency | typ. 91 % (400 V AC) |
| Insulation voltage input/output | 3 kV AC (type test) |
| 1.5 kV AC (routine test) | |
| Protection class | II (in closed control cabinet) |
| Degree of protection | IP20 |
| MTBF (IEC 61709, SN 29500) | > 2300000 h (25 °C) |
| > 1300000 h (40 °C) | |
| > 620000 h (60 °C) | |
| Assembly instructions | Cross Power System |
Connection data, output
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
Connection data for signaling
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Standards
| EMC requirements for noise immunity | EN 61000-6-2 |
|---|---|
| Standard - Safety of transformers | EN 61558-2-16 (air clearances and creepage distances only) |
| Standard - Electrical safety | IEC 61010-1 (SELV) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard – Safety extra-low voltage | IEC 61010 (SELV) / (PELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
EMC data
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Conducted noise emission | EN 55016 |
| EN 61000-6-4 (Class A) | |
| Noise emission | EN 55016 |
| EN 61000-6-4 (Class A) | |
| Electrostatic discharge | EN 61000-4-2 |
| Contact discharge | 6 kV (Test Level 4) |
| Discharge in air | 8 kV (Test Level 4) |
| Electromagnetic HF field | EN 61000-4-3 |
| Frequency range | 80 MHz ... 1 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Frequency range | 1 GHz ... 2 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Frequency range | 2 GHz ... 3 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Comments | Criterion A |
| Fast transients (burst) | EN 61000-4-4 |
| Input | 4 kV (Test Level 4 - asymmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Comments | Criterion A |
| Input | 3 kV (Test Level 3 - symmetrical) |
| 6 kV (Test Level 4 - asymmetrical) | |
| Output | 1 kV (Test Level 2 - symmetrical) |
| 2 kV (Test Level 1 - asymmetrical) | |
| Signal | 1 kV (Test Level 1 - symmetrical) |
| Comments | Criterion B |
| Voltage dips | EN 61000-4-11 |
| Voltage | 230 V AC |
| Frequency | 50 Hz |
| Voltage dip | 70 % |
| Number of periods | 25 periods |
| Additional text | Test Level 2 |
| Comments | Criterion A |
| Voltage dip | 40 % |
| Number of periods | 10 periods |
| Additional text | Test Level 2 |
| Comments | Criterion A |
| Voltage dip | 0 % |
| Number of periods | 1 period |
| Additional text | Test Level 2 |
| Comments | Criterion A |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |