View larger
ELR 1-SC-230AC/600AC-20 1032920 PHOENIX CONTACT Single-phase solid-state contactor, input voltage: 230 V AC,..
ELR 1-SC-230AC/600AC-20
1032920
PHOENIX CONTACT
1 Pcs.
Automation > Power contactor, AC switching
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact Single-phase solid-state contactor, input voltage: 230 V AC,.. provides silent, wear-free electronic switching for alternating current loads in industrial automation and heating control setups. By eliminating mechanical contacts, it ensures exceptionally long operating lifespans and rapid switching frequencies in demanding production environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Solid-state contactor
- Data management status Article revision: 01
- Number of phases: 1
- Maximum power dissipation for nominal condition: 20 W
- Mains type: 1-phase
- Control Input name: Control input
- Rated actuating voltage U C: 230 V AC
- Triggering voltage range: 24 V AC ... 275 V AC
- Rated actuating current I C: approx. 17 mA
- Switching threshold: ≤ 5 V AC/DC (“0” signal
- Operating voltage display: Green LED
- Transmission frequency: 6 Hz
- Load output Operating voltage range: 42 V AC ... 660 V AC
- Rated operating current at AC-51: 20 A
- Rated operating current at AC-53a: 5 A (T A = 25 °C)
- Peak offstate voltage: 1200 V
More info
▲| Product type | Solid-state contactor |
| Data management status | |
| Article revision | 01 |
| Number of phases | 1 |
| Maximum power dissipation for nominal condition | 20 W |
| Mains type | 1-phase |
| Control | |
| Input name | Control input |
| Rated actuating voltage UC | 230 V AC |
| Triggering voltage range | 24 V AC ... 275 V AC |
| 24 V DC ... 190 V DC | |
| Rated actuating current IC | approx. 17 mA |
| Switching threshold | ≤ 5 V AC/DC (“0” signal) |
| ≥ 20 V AC/DC (“1” signal) | |
| Operating voltage display | Green LED |
| Transmission frequency | 6 Hz |
| Load output | |
| Operating voltage range | 42 V AC ... 660 V AC |
| Rated operating current at AC-51 | 20 A |
| Rated operating current at AC-53a | 5 A (TA= 25 °C) |
| 5 A (TA= 40 °C) | |
| Peak offstate voltage | 1200 V |
| Mains frequency | 45 Hz |
| 65 Hz | |
| Load current range | 150 mA ... 20 A (see to derating) |
| Leakage current | < 3 mA (In off state) |
| Residual voltage | < 1 V |
| Surge current | 325 A (t = 10 ms) |
| Max. load value | 525 A2s |
| Protective circuit | Varistor |
| Phase angle cos phi min | 0.5 |
| Control circuits | |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.5 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section AWG | 18 ... 12 |
| Load circuit | |
| Connection method | Screw connection |
| Stripping length | 12 mm |
| Screw thread | M4 |
| Conductor cross section rigid | 2.5 mm² ... 6 mm² |
| Conductor cross section flexible | 1 mm² ... 4 mm² |
| Conductor cross section AWG | 14 ... 10 |
| Protective conductor connection | |
| Connection method | Ring cable lug |
| Screw thread | M5 |
| Tightening torque | 1.5 Nm |
| Operating voltage display | Green LED |
| Width | 18 mm |
| Height | 110 mm |
| Depth | 103 mm |
| Color | gray (RAL 7042) |
| Ambient conditions | |
| Ambient temperature (operation) | -30 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Standards/regulations | |
| Standards/regulations | EN 61000-4-2 |
| EN 61000-4-3 | |
| EN 61000-4-4 | |
| EN 61000-4-5 | |
| EN 55011 | |
| Mounting type | DIN rail mounting |
| Assembly note | Can be aligned with ≥ 22.5 mm spacing |
| Mounting position | Vertical (horizontal DIN rail) |