Phoenix Contact EEM-EM355 is a specialized energy meter engineered to measure electrical energy consumption and monitor circuit parameters in heavy electrical distribution setups. It handles wide input ranges and supports transformer integration for large industrial facilities.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Energy meter
- Data management status Article revision: 04
- Insulation characteristics Protection class: II (EN 50470-1)
- Insulation characteristics Pollution degree: 2
- Electric strength: 6 kV
- Supply Supply voltage range: Supply from the measuring circuit
- Measurement Input voltage range: 3x 184 V ... 288 V (320 V ... 500 V)
- Input current range: up to transformer ratio 10000
- Power consumption: 3.5 VA (1 W)
- Frequency range: 45 Hz ... 65 Hz
- Start current I st: 0.002 A
- Minimal current I min: 0.01 A
- Maximum current I max: 6 A
- Transient current I tr: 0.05 A
- Nominal current I ref: 1 A
- Secondary rated current I sn: 1 A
More info
▲| Product type | Energy meter |
| Data management status | |
| Article revision | 04 |
| Insulation characteristics | |
| Protection class | II (EN 50470-1) |
| Insulation characteristics | |
| Pollution degree | 2 |
| Electric strength | 6 kV |
| 4 kV (EN 50470-3, 7.2) | |
| Supply | |
| Supply voltage range | Supply from the measuring circuit |
| Measurement | |
| Input voltage range | 3x 184 V ... 288 V (320 V ... 500 V) |
| Input current range | up to transformer ratio 10000 |
| Power consumption | 3.5 VA (1 W) |
| Frequency range | 45 Hz ... 65 Hz |
| Start current Ist | 0.002 A |
| Minimal current Imin | 0.01 A |
| Maximum current Imax | 6 A |
| Transient current Itr | 0.05 A |
| Nominal current Iref | 1 A |
| Secondary rated current Isn | 1 A |
| 5 A | |
| Current transformer ratio | 1 ... 10000 (max. 10000/1 or 50000/5) |
| Current transformer load | 1.5 mΩ |
| Energy (EN 50470-3) | Class B |
| Real energy (IEC 62053-21) | Class 1 |
| Reactive power (IEC 62053-23) | Class 2 |
| Digital | |
| Description of the input | Active opto-isolated |
| Input voltage range | 80 V AC/DC ... 276 V AC/DC |
| S0 output | |
| Output description | Passive opto-isolated |
| Maximum switching voltage | 27 V DC |
| Max. switching current | 27 mA |
| Pulse time | 50 ms ±2 ms |
| Pause time | 30 ms ±2 ms |
| Pulse LED | 10000 imp/kWh |
| Meter constant | 100 imp/kWh, kVAh, kvarh |
| 1000 imp/kWh, kVAh, kvarh (CT 1 ... 4) | |
| 200 imp/kWh, kVAh, kvarh (CT 5 ... 24) | |
| 40 imp/kWh, kVAh, kvarh (CT 25 ... 124) | |
| 8 imp/kWh, kVAh, kvarh (CT 125 ... 624) | |
| 1 imp/kWh, kVAh, kvarh (CT 625 ... 3124) | |
| 0.1 imp/kWh, kVAh, kvarh (CT 3125 ... 10000) | |
| Measurement connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 1.5 mm² ... 6 mm² |
| Conductor cross section flexible | 1.5 mm² ... 6 mm² |
| Conductor cross section AWG | 16 ... 10 (rigid/flexible) |
| Tightening torque | 1.5 Nm |
| Other connections | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG | 26 ... 16 (rigid/flexible) |
| Tightening torque | 0.5 Nm |
| Communication: | |
| Communication protocol | Modbus |
| Communication standard | RS-485 |
| Transmission speed range | 300 bps ... 57600 bps |
| Parity | odd, even, none |
| Width | 72 mm |
| Height | 90 mm |
| Depth | 67 mm |
| Ambient conditions | |
| Degree of protection (Front) | IP51 (Front) |
| Degree of protection (Connections) | IP20 (Connections) |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -25 °C ... 75 °C |
| Max. permissible relative humidity (operation) | 80 % |
| CE | |
| Certificate | CE-compliant |
| MID | |
| Identification | MID-compliant |
| Standards/specifications | EN 50470-1 |
| EN 50470-3 |