PHOENIX CONTACT EEM-EM355 EEM-EM355 2908578 PHOENIX CONTACT Measuring instrument View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EEM-EM355 2908578 PHOENIX CONTACT Measuring instrument

EEM-EM355

2908578

PHOENIX CONTACT

1 Pcs.

Measuring instrument Three-phase energy meter for measuring active power with 1 A / 5 A transformer measurement in networks up to 500 V, with S0 output, with digital input and RS-485 interface, certified according to the MID directive 3-phase energy meter for active power measurement with current transformer measurement 1 A/5 A in grids of up to 500 V, with S0 output, with digital input and RS-485 interface, certified in accordance with the MID directive

Automation > Multifunction measuring instrument
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact EEM-EM355 is a specialized energy meter engineered to measure electrical energy consumption and monitor circuit parameters in heavy electrical distribution setups. It handles wide input ranges and supports transformer integration for large industrial facilities.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Energy meter
  • Data management status Article revision: 04
  • Insulation characteristics Protection class: II (EN 50470-1)
  • Insulation characteristics Pollution degree: 2
  • Electric strength: 6 kV
  • Supply Supply voltage range: Supply from the measuring circuit
  • Measurement Input voltage range: 3x 184 V ... 288 V (320 V ... 500 V)
  • Input current range: up to transformer ratio 10000
  • Power consumption: 3.5 VA (1 W)
  • Frequency range: 45 Hz ... 65 Hz
  • Start current I st: 0.002 A
  • Minimal current I min: 0.01 A
  • Maximum current I max: 6 A
  • Transient current I tr: 0.05 A
  • Nominal current I ref: 1 A
  • Secondary rated current I sn: 1 A

More info

▲
Technical data

Product properties
Product typeEnergy meter
Data management status
Article revision04
Insulation characteristics
Protection classII (EN 50470-1)
Insulation characteristics
Pollution degree2

Electrical properties
Electric strength6 kV
4 kV (EN 50470-3, 7.2)
Supply
Supply voltage rangeSupply from the measuring circuit

Input data
Measurement
Input voltage range3x 184 V ... 288 V (320 V ... 500 V)
Input current rangeup to transformer ratio 10000
Power consumption3.5 VA (1 W)
Frequency range45 Hz ... 65 Hz
Start current Ist0.002 A
Minimal current Imin0.01 A
Maximum current Imax6 A
Transient current Itr0.05 A
Nominal current Iref1 A
Secondary rated current Isn1 A
5 A
Current transformer ratio1 ... 10000 (max. 10000/1 or 50000/5)
Current transformer load1.5 mΩ
Energy (EN 50470-3)Class B
Real energy (IEC 62053-21)Class 1
Reactive power (IEC 62053-23)Class 2
Digital
Description of the inputActive opto-isolated
Input voltage range80 V AC/DC ... 276 V AC/DC

Output data
S0 output
Output descriptionPassive opto-isolated
Maximum switching voltage27 V DC
Max. switching current27 mA
Pulse time50 ms ±2 ms
Pause time30 ms ±2 ms
Pulse LED10000 imp/kWh
Meter constant100 imp/kWh, kVAh, kvarh
1000 imp/kWh, kVAh, kvarh (CT 1 ... 4)
200 imp/kWh, kVAh, kvarh (CT 5 ... 24)
40 imp/kWh, kVAh, kvarh (CT 25 ... 124)
8 imp/kWh, kVAh, kvarh (CT 125 ... 624)
1 imp/kWh, kVAh, kvarh (CT 625 ... 3124)
0.1 imp/kWh, kVAh, kvarh (CT 3125 ... 10000)

Connection data
Measurement connection
Connection methodScrew connection
Conductor cross section rigid1.5 mm² ... 6 mm²
Conductor cross section flexible1.5 mm² ... 6 mm²
Conductor cross section AWG16 ... 10 (rigid/flexible)
Tightening torque1.5 Nm
Other connections
Connection methodScrew connection
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section AWG26 ... 16 (rigid/flexible)
Tightening torque0.5 Nm

Interfaces
Communication:
Communication protocolModbus
Communication standardRS-485
Transmission speed range300 bps ... 57600 bps
Parityodd, even, none

Dimensions
Width72 mm
Height90 mm
Depth67 mm

Environmental and real-life conditions
Ambient conditions
Degree of protection (Front)IP51 (Front)
Degree of protection (Connections)IP20 (Connections)
Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C
Max. permissible relative humidity (operation)80 %

Approvals
CE
CertificateCE-compliant
MID
IdentificationMID-compliant

Standards and regulations
Standards/specificationsEN 50470-1
EN 50470-3

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.