View larger
Images are for illustrative purposes only. Please refer to data sheet for details
ECS-B-122X169-L-UV-NV GY 1050212 PHOENIX CONTACT Snap-in locking non-vented enclosure of the ECS Family. IP6..
ECS-B-122X169-L-UV-NV GY
1050212
PHOENIX CONTACT
5 Pcs.
Snap-in locking non-vented enclosure of the ECS Family. IP66/67/69 rated when mated with associated faceplate. Color: Grey (7042), Width: 170 mm, Height: 176 mm, Depth: 64 mm
Non-ventilated housing from the ECS family, locking by socket. IP66/67/69 protection rating in case of combination with the corresponding faceplate. Colour: grey (7042), width: 170 mm, height: 176 mm, depth: 64 mm
Automation > Extruded profile modular housing
Housing (HS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for demanding field locations, this outdoor housing unit protects sensitive electrical hardware and printed circuit board assemblies from moisture, dust, and physical damage.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Assembly note: Refer to the data sheet for the range in the download area.
- Product type: Housing
- Housing type: Outdoor housing
- Housing series: ECS
- Product family: ECS..122X..L..
- Type: non-vented
- Data management status Article revision: 00
- Width: 170 mm
- Height: 176 mm
- Depth: 64 mm
- PCB design PCB thickness: 1.57 mm ... 2.36 mm
- Color (Housing): gray (RAL 7042)
- Flammability rating according to UL 94: V0
- Housing material: PC (polycarbonate)
- Surface characteristics: untreated
- Vibration test Specification: IEC 60068-2-6:2007-12
More info
▲Technical data
Notes
| Assembly note | Refer to the data sheet for the range in the download area. |
Product properties
| Product type | Housing |
| Housing type | Outdoor housing |
| Housing series | ECS |
| Product family | ECS..122X..L.. |
| Type | non-vented |
| Data management status | |
| Article revision | 00 |
Dimensions
| Dimensional drawing | |
| Width | 170 mm |
| Height | 176 mm |
| Depth | 64 mm |
| PCB design | |
| PCB thickness | 1.57 mm ... 2.36 mm |
Material specifications
| Color (Housing) | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Housing material | PC (polycarbonate) |
| Surface characteristics | untreated |
Environmental and real-life conditions
| Vibration test | |
| Specification | IEC 60068-2-6:2007-12 |
| Frequency | 10 - 2000 - 10 Hz |
| Sweep speed | 1 octave/min |
| Acceleration | 15g (61.6 Hz ... 2000 Hz) |
| Test duration per axis | 2.5 h |
| Test directions | X-, Y- and Z-axis |
| Glow-wire test | |
| Specification | IEC 60695-2-11:2014-02 |
| Temperature | 850 °C |
| Time of exposure | 30 s |
| Mechanical strength / tumbling barrel | |
| Specification | IEC 60068-2-31:2008-05 |
| Height of fall | 50 cm |
| Frequency | 50 |
| Shocks | |
| Specification | IEC 60068-2-27:2008-02 |
| Pulse shape | Semi-sinusoidal |
| Acceleration | 50g |
| Shock duration | 11 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Salt spray test | |
| Specification | DIN EN 60068-2-11:2000-02 |
| Test duration | 96 h |
| Test for substances that would hinder coating with paint or varnish | |
| Specification | VDMA 24364:2018-05 |
| Result | Test passed |
| Degree of protection (IP code) | |
| Specification | IEC 60529:1989-11 + AMD 1:1999-11 + AMD 2:2013-08 |
| Result, degree of protection, IP code | IP66/IP68 (2 m/24 h) |
| Ambient conditions | |
| Degree of protection | IP66/IP67 |
| Max. NEMA code to attain | 6 |
| Impact strength | IK08 |
| Ambient temperature (operation) | -40 °C ... 100 °C |
| Ambient temperature (storage/transport) | -40 °C ... 100 °C |
PCB data
| Number of PCB holders | 1 |
| Thickness of the PCB | 1.57 mm ... 2.36 mm |
Mounting
| Mounting type | Wall or panel mount. Pole mount with accessory. |