View larger
FBP-2/I19 3069678 PHOENIX CONTACT Dummy plug
FBP-2/I19
3069678
PHOENIX CONTACT
1 Pcs.
Automation > Installation clamp for meters
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact FBP-2/I19 dummy plug is designed to fill multiple unused positions in modular terminal block assemblies, preventing environmental contamination. Multi-position blind plugs help keep unused channels secure and mechanically sound in complex control panels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Blind plug
- Number of positions: 19
- Pitch: 8.2 mm
- Data management status Article revision: 05
- Width: 187.5 mm
- Height: 81 mm
- Pitch: 8.2 mm
- Color: gray (RAL 7042)
- Flammability rating according to UL 94: V0
- Insulating material: PA
- Static insulating material application in cold: -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
- Calorimetric heat release NFPA 130 (ASTM E 1354): 27,5 MJ/kg
More info
▲| Product type | Blind plug |
| Number of positions | 19 |
| Pitch | 8.2 mm |
| Data management status | |
| Article revision | 05 |
| Width | 187.5 mm |
| Height | 81 mm |
| Pitch | 8.2 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | Insertion in base strip |