Serving as a secure component, the Phoenix Contact FBP-2/4 blind plug prevents unintended access or dust ingress within unused connection spaces. Dummy plugs are frequently utilized in modular terminal configurations to maintain neat panel layouts and protect internal wiring from environmental exposure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Blind plug
- Number of positions: 4
- Pitch: 8.2 mm
- Data management status Article revision: 03
- Insulation characteristics Overvoltage category: III
- Width: 65.2 mm
- Height: 72.9 mm
- Pitch: 8.2 mm
- Color: gray (RAL 7042)
- Material: PA
- Flammability rating according to UL 94: V0
- Insulating material group: I
- Static insulating material application in cold: -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
More info
▲| Product type | Blind plug |
| Number of positions | 4 |
| Pitch | 8.2 mm |
| Data management status | |
| Article revision | 03 |
| Insulation characteristics | |
| Overvoltage category | III |
| Width | 65.2 mm |
| Height | 72.9 mm |
| Pitch | 8.2 mm |
| Color | gray (RAL 7042) |
| Material | PA |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | Insertion in base strip |