PHOENIX CONTACT ST 2,5-QUATTRO-TG ST 2,5-QUATTRO-TG 3038451 PHOENIX CONTACT Disconnect terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ST 2,5-QUATTRO-TG 3038451 PHOENIX CONTACT Disconnect terminal block

ST 2,5-QUATTRO-TG

3038451

PHOENIX CONTACT

50 Pcs.

Disconnect terminal block Interruptible terminal block, The maximum load current must not be exceeded by the sum current of all connected conductors. The current and voltage are determined by the connector used., rated voltage: 400 V, rated current: 20 A, 1st floor, connection type: Spring connection, Sizing section: 2.5 mm², cross-section: 0.08 mm² - 4 mm², mounting: NS 35/7.5, NS 35/15, color: gray Disconnect terminal block, The max. load current must not be exceeded by the total current of all connected conductors.Current and voltage are determined by the plug used., nom. voltage: 400 V, Thermal continuous current Ith: 20 A, connection method: Spring-cage connection, Rated cross section: 2.5 mm2, cross section: 0.08 mm2 - 4 mm2, mounting: NS 35/7,5, NS 35/15, color: gray

Automation > (Knife) disconnect terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Engineered for demanding railway applications, the Phoenix Contact ST 2,5-QUATTRO-TG disconnect terminal block provides robust signal separation and distribution within rolling stock electrical architectures. Modular disconnect blocks allow technicians to isolate specific sub-circuits safely during routine maintenance and diagnostic testing operations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Disconnect terminal block
  • Area of application: Railway industry
  • Number of connections: 4
  • Number of rows: 1
  • Potentials: 1
  • Data management status Article revision: 06
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Rated surge voltage: 6 kV
  • Maximum power dissipation for nominal condition: 0.77 W
  • Number of connections per level: 4
  • Nominal cross section: 2.5 mm²
  • Stripping length: 8 mm ... 10 mm
  • Internal cylindrical gage: A3
  • Connection in acc. with standard: IEC 60947-7-1
  • Conductor cross section rigid: 0.08 mm² ... 4 mm²

More info

Technical data

Notes
GeneralThe max. load current must not be exceeded by the total current of all connected conductors.
Current and voltage are determined by the plug used.
General
NoteThe max. load current must not be exceeded by the total current of all connected conductors.

Product properties
Product typeDisconnect terminal block
Area of applicationRailway industry
Machine building
Plant engineering
Number of connections4
Number of rows1
Potentials1
Data management status
Article revision06
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage6 kV
Maximum power dissipation for nominal condition0.77 W

Connection data
Number of connections per level4
Nominal cross section2.5 mm²
Stripping length8 mm ... 10 mm
Internal cylindrical gageA3
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.08 mm² ... 4 mm²
Cross section AWG28 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.08 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]28 ... 14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm²
Thermal continuous current Ith20 A (with 4 mm² conductor cross section)
Maximum load current20 A (with 4 mm² conductor cross section)
Nominal voltage400 V (voltage is determined by the plug used)
Nominal cross section2.5 mm²

Dimensions
Width5.2 mm
End cover width2.2 mm
Height84 mm
Depth on NS 35/7,536.5 mm
Depth on NS 35/1544 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Electrical tests
Surge voltage test
Test voltage setpoint6 kV
ResultTest passed
Temperature-rise test
Requirement temperature-rise testIncrease in temperature ≤ 45 K
ResultTest passed
Short-time withstand current 2.5 mm²0.3 kA
ResultTest passed
Power-frequency withstand voltage
Test voltage setpoint1.89 kV
ResultTest passed

Mechanical properties
Mechanical data
Open side panelYes

Mechanical tests
Mechanical strength
ResultTest passed
Attachment on the carrier
Test force setpoint1 N
ResultTest passed
Test for conductor damage and slackening
Rotation speed10 (+/- 2) rpm
Revolutions135
Conductor cross section/weight0.08 mm² / 0.1 kg
2.5 mm² / 0.7 kg
4 mm² / 0.9 kg
ResultTest passed

Environmental and real-life conditions
Aging
Temperature cycles192
ResultTest passed
Needle-flame test
Time of exposure30 s
ResultTest passed
Oscillation/broadband noise
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
SpectrumService life test category 2, bogie-mounted
Frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s²)²/Hz
Acceleration3.12g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed
Shocks
SpecificationDIN EN 50155 (VDE 0115-200):2008-03
Pulse shapeHalf-sine
Acceleration5g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-1

Mounting
Mounting typeNS 35/7,5
NS 35/15

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.