View larger
RAD-DOR4-IFS 2901536 PHOENIX CONTACT I/O extension module
RAD-DOR4-IFS
2901536
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - digital I/O module
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing expanded signal pathways, the Phoenix Contact RAD-DOR4-IFS acts as an I/O extension module for remote telemetry and wireless automation setups. These expansion units allow control systems to monitor and switch discrete field devices across extended industrial plant distances.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Number of digital inputs (EF001992): 0
- Number of digital outputs (EF001993): 4
- Digital inputs configurable (EF008516): No
- Digital outputs configurable (EF008520): No
- Type of voltage (input voltage) (EF003033): DC
- Type of digital output (EF003601): Relay
- Output current (EF003202): 5 A
- Short-circuit protection, outputs available (EF003203): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
More info
▲Key Commercial Data
| Orderkey | 2901536 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 461 (C-6-2017) |
| GTIN | 4046356610483 |
| Weight per Piece (excluding packing) | 179.400 g |
| Custom tariff number | 85177000 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 70 °C (>55°C derating) |
| -40 °F ... 158 °F (>131°F derating) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| -40 °F ... 185 °F | |
| Permissible humidity (operation) | 20 % ... 85 % |
| Permissible humidity (storage/transport) | 20 % ... 85 % |
| Altitude | 2000 m |
| Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
| Shock | 16g, 11 ms |
General
| Overvoltage category | II |
|---|---|
| Mounting position | any |
| Assembly instructions | on standard DIN rail NS 35 in accordance with EN 60715 |
| Degree of pollution | 2 |
| Housing material | PA 6.6-FR |
| Flammability rating according to UL 94 | V0 |
| MTTF | 1087 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| 523 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| 204 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
Supply
| Supply voltage range | 19.2 V DC ... 30.5 V DC (DIN rail connector) |
|---|---|
| Max. current consumption | ≤ 55 mA (At 24 V DC, at 25°C) |
| Transient surge protection | Yes |
Digital outputs
| Number of outputs | 4 |
|---|---|
| Contact type | PDT |
| Contact material | AgSnO2 |
| Maximum switching voltage | 250 V AC/DC |
| Min. switching current | ≥ 10 mA |
| Max. switching current | 5 A (per channel) |
| Mechanical service life | 1x 107cycles |
| Electrical service life | 1x 105cycles (At 5 A, 250 V AC, ohmic) |
| 2x 105cycles (At 2 A, 250 V AC, cosφ 0.4) | |
| 2x 105cycles (At 1 A, 24 V DC, L/R = 48 ms) | |
| Maximum switching frequency | 2 Hz |
| Switching capacity | 120 W (24 V DC) |
| 120 W (30 V DC) | |
| 20 W (48 V DC) | |
| 18 W (60 V DC) | |
| 22 W (110 V DC) | |
| 40 W (220 V DC) | |
| 42 W (250 V DC) | |
| 1250 VA | |
| Behavior of the outputs (adjustable via DIP switch) | Hold / Reset |
Electrical isolation
| Digital I/O | 300 V (Rated insulation voltage (in each case between the digital outputs // TBUS supply, reinforced insulation according to EN 61010)) |
|---|
Connection data
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Tightening torque | 0.6 Nm |
| Screw thread | M3 |
Status indicator
| Status display | Green LED (supply voltage, PWR) |
|---|---|
| Green LED (bus communication, DAT) | |
| Red LED (periphery error, ERR) | |
| Yellow LED (digital output, DO1) | |
| Yellow LED (digital output, DO2) | |
| Yellow LED (digital output, DO3) | |
| Yellow LED (digital output, DO4) |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Standard designation | EMC Directive 2014/30/EU |
| Standards/regulations | EN 61000-6-2 |
| Standard designation | EMC Directive 2014/30/EU |
| Standards/regulations | EN 61000-6-4 |
| Standard designation | Ex Directive (ATEX) |
| Standards/regulations | EN 60079-0 |
| Standard designation | Ex Directive (ATEX) |
| Standards/regulations | EN-60079-15 |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Flammability rating according to UL 94 | V0 |
| Shock | 16g, 11 ms |
| Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC IIC T4 Gc |
| IECEx | Ex nA nC IIC T4 Gc |
| UL, USA/Canada | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T4A | |
| Class I, Zone 2, IIC T4 | |
| Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |