View larger
CSS 0.55-1/3 1201494 PHOENIX CONTACT Speed starter with soft start and adjustable speed for starting and rev..
CSS 0.55-1/3
1201494
PHOENIX CONTACT
1 Pcs.
Automation > Speed controller
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact CSS 0.55-1/3 functions as a variable speed starter to handle motor startup ramps and operational speed adjustments in factory automation lines. Devices of this category protect system mechanics from excessive torque impacts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Variable Speed Starter
- Product Family: CONTACTRON
- Operating elements: Key
- Insulation characteristics Degree of pollution: 2
- Number of phases: 1
- Network Number of phases: 1
- Input voltage: 230 V AC
- Input voltage range: 110 V AC ... 240 V AC -15 % ... +10 %
- Frequency: 47 Hz ... 63 Hz
- Rated current: 6.7 A (without mains choke)
- Motor rated power: 0.55 kW
- Apparent power: 1.3 kVA
- Rated output current (I N ): 3.2 A (4 kHz)
- Output Frequency: 0 Hz ... 500 Hz
- Power dissipation: 29 W (2 kHz)
- Output current: ≤ 4.8 A (180 s)
More info
▲| Product Type | Variable Speed Starter |
| Product Family | CONTACTRON |
| Operating elements | Key |
| Selector | |
| Insulation characteristics | |
| Degree of pollution | 2 |
| Number of phases | 1 |
| Network | |
| Number of phases | 1 |
| Input voltage | 230 V AC |
| 240 V AC | |
| Input voltage range | 110 V AC ... 240 V AC -15 % ... +10 % |
| Frequency | 47 Hz ... 63 Hz |
| Rated current | 6.7 A (without mains choke) |
| 6.2 A (with mains choke) | |
| Motor rated power | 0.55 kW |
| Apparent power | 1.3 kVA |
| Rated output current (IN) | 3.2 A (4 kHz) |
| 2.6 A (8 kHz) | |
| 1.8 A (16 kHz) | |
| Output Frequency | 0 Hz ... 500 Hz |
| Power dissipation | 29 W (2 kHz) |
| 33 W (4 kHz) | |
| 32 W (8 kHz) | |
| 30 W (16 kHz) | |
| 9 W (Standby) | |
| Output current | ≤ 4.8 A (180 s) |
| ≤ 2.4 A (180 s, during restore time) | |
| ≤ 5.76 A (15 s) | |
| ≤ 1.6 A (15 s, during reset time) | |
| Reset Time | 150 s (180 s) |
| 12 s (15 s) | |
| Overload Time | 30 s (180 s) |
| 3 s (15 s) | |
| Discharge time | 3 min. (Intermediate Circuit Capacitors) |
| Switching | |
| Output Name | Relay output |
| Contact Switching Type | 1 diverter contact |
| Max. switchable voltage | 125 V AC |
| 30 V DC | |
| Max. inrush current | 3 A |
| Min. Insertion Current | 10 mA (5 V DC) |
| Conductor cross-section AWG | (converted according to IEC) |
| Power terminals | |
| Link | Push-in connection |
| Stripping length | 10 mm |
| Rigid conductor cross-section | 0.2 mm² ... 6 mm² |
| Flexible conductor cross-section | 0.2 mm² ... 6 mm² |
| 0.2 mm² ... 4 mm² (with lug) | |
| Conductor cross-section AWG | 24 ... 10 |
| Control Terminals | |
| Link | Push-in connection |
| Stripping length | 10 mm |
| Rigid conductor cross-section | 0.2 mm² ... 1.5 mm² (with lug) |
| Flexible conductor cross-section | 0.2 mm² ... 1.5 mm² |
| 0.2 mm² ... 0.75 mm² | |
| Conductor cross-section AWG | 24 ... 16 |
| Hole | |
| Diameter | 5.5 mm |
| width | 45 mm |
| height | 210 mm |
| Depth | 190 mm |
| length | ≤ 50 m (EMC Category C2 Compliant) |
| ≤ 50 m (EMC Category C3 Compliant) | |
| ≤ 50 m (without EMC compliance) | |
| Environmental conditions | |
| Degree of protection (IP) | Ip20 |
| Degree of protection (NEMA) | NEMA 1 |
| Ambient temperature (operating) | -20 °C ... 55 °C (without current derating) |
| -20 °C ... 60 °C (with linear current derating) | |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Elevated position | ≤ 2000 m |
| > 2000 m (with derating) | |
| Permissible humidity (operation) | 90 % (non-condensing) |
| Permissible humidity (storage/transport) | 95 % (non-condensing) |
| Shocks (exercise) | 15g, 11ms |
| Vibration (exercise) | 0.075 mm / 1g |
| Air pressure (operation) | 86 kPa ... 106 kPa |
| Air pressure (transport and storage) | 70 kPa ... 106 kPa |
| Safety Integrity Level (SIL, IEC 61800-5-2) | |
| Marking | 3 |
| Performance Level (EN ISO 13849) | |
| Marking | and |
| Category (ISO 13849) | |
| Marking | 4 |
| Standards/Provisions | IEC 61800-5-1 |
| IEC 61800-3 |
| Mounting type | Rail Mounting |
| Wall Mounting |