View larger
PSR-SPP- 24DC/FSP2/2X1/1X2 2986588 PHOENIX CONTACT Coupling relay
PSR-SPP-24DC/FSP2/2X1/1X2
2986588
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A coupling relay is an electromechanical interface component used to isolate control circuits from load circuits, ensuring signal matching and basic safety switching in industrial control panels. The Phoenix Contact PSR-SPP-24DC/FSP2/2X1/1X2 features spring clamp connections and a compact modular housing designed for efficient DIN rail installation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Spring clamp connection
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): No
- Release-delay (EF001129): 0.05 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 17.5 mm
- Height (EF000040): 112 mm
More info
▲Key Commercial Data
| Orderkey | 2986588 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 287 (C-6-2017) |
| GTIN | 4046356553339 |
| Weight per Piece (excluding packing) | 138.900 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
|---|---|
| Rated control supply current IS | typ. 55 mA |
| Power consumption at US | typ. 1.32 W |
| Inrush current | max. 100 mA |
| Typ. starting time with Us | 50 ms |
| Typical release time | 50 ms |
| Recovery time | 1 s |
| Operating voltage display | 1 x yellow LED |
| Protective circuit | Surge protection Suppressor diode, 33 V (A1 - A2) |
| Maximum switching frequency | 0.5 Hz |
| Filter time | max. 5 ms (at A1 in the event of voltage dips at Us) |
| max. 2 ms (Test pulse width; high test pulse at A1/A2) | |
| ≥ 100 ms (Test pulse width; high test pulse at A1/A2) | |
| Test pulse rate = 80 x Test pulse width | |
| max. 5 ms (Test pulse width; low test pulse at A1/A2) | |
| ≥ 50 ms (Test pulse rate; low test pulse at A1/A2) | |
| Test pulse rate = 15 x Test pulse width |
Output data
| Contact type | 2 enabling current paths |
|---|---|
| 1 confirmation current path | |
| Contact material | AgCuNi, + 0.2 µm Au |
| Maximum switching voltage | 250 V AC/DC (N/O contact / N/C contact, observe the load curve) |
| Minimum switching voltage | 15 V AC/DC (N/O contact / N/C contact) |
| Limiting continuous current | 5 A (N/O contact, pay attention to the derating) |
| 100 mA (N/C contact) | |
| Maximum inrush current | 5 A (N/O contact) |
| 100 mA (N/C contact) | |
| Inrush current, minimum | 5 mA (N/O contact / N/C contact) |
| Sq. Total current | 50 A2(observe derating) |
| Interrupting rating (ohmic load) max. | 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W) |
| 192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W) | |
| 162 W (60 V DC, τ = 0 ms, N/C contact: 6 W) | |
| 66 W (110 V DC, τ = 0 ms, N/C contact: 11 W) | |
| 60 W (220 V DC, τ = 0 ms, N/C contact: 22 W) | |
| 1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA) | |
| Maximum interrupting rating (inductive load) | 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W) |
| 43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W) | |
| 41 W (60 V DC, τ = 40 ms, N/C contact: 6 W) | |
| 35 W (110 V DC, τ = 40 ms, N/C contact: 11 W) | |
| 48 W (220 V DC, τ = 40 ms, N/C contact: 22 W) | |
| Switching capacity | min. 75 mW |
| Mechanical service life | 10x 106cycles |
| Output fuse | 10 A gL/gG (N/O contact) |
| 4 A gL/gG (for low-demand applications) | |
| 150 mA Fast-blow (N/C contact) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 138.9 g |
| Mounting position | any |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
Connection data
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Designation | EN ISO 13849 |
| Performance level (PL) | c (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
| Category | 1 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 1 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | 2 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (31/32), (13/14, 23/24) |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |