View larger
PSR-SCP- 24DC/FSP/1X1/1X2 2981978 PHOENIX CONTACT Coupling relay
PSR-SCP-24DC/FSP/1X1/1X2
2981978
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PSR-SCP-24DC/FSP/1X1/1X2 coupling relay is designed to electrically isolate control signals and safely switch auxiliary circuits within industrial automation infrastructure. Such devices are commonly deployed in machinery control panels to interface low-voltage controllers with higher-voltage load circuits while protecting sensitive electronics. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): No
- Release-delay (EF001129): 0.05 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 17.5 mm
- Height (EF000040): 99 mm
More info
▲Key Commercial Data
| Orderkey | 2981978 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 286 (C-6-2017) |
| GTIN | 4046356448352 |
| Weight per Piece (excluding packing) | 185.000 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
|---|---|
| Rated control supply current IS | typ. 55 mA |
| Power consumption at US | typ. 1.32 W |
| Inrush current | max. 100 mA |
| Typ. starting time with Us | 50 ms |
| Typical release time | 50 ms |
| Recovery time | 1 s |
| Operating voltage display | 1 x yellow LED |
| Protective circuit | Surge protection Suppressor diode, 33 V (A1 - A2) |
| Maximum switching frequency | 0.5 Hz |
| Filter time | max. 5 ms (at A1 in the event of voltage dips at Us) |
| max. 2 ms (Test pulse width; high test pulse at A1/A2) | |
| ≥ 100 ms (Test pulse width; high test pulse at A1/A2) | |
| Test pulse rate = 80 x Test pulse width | |
| max. 5 ms (Test pulse width; low test pulse at A1/A2) | |
| ≥ 50 ms (Test pulse rate; low test pulse at A1/A2) | |
| Test pulse rate = 15 x Test pulse width |
Output data
| Contact type | 1 enabling current path |
|---|---|
| 1 confirmation current path | |
| Contact material | AgCuNi, + 0.2 µm Au |
| Maximum switching voltage | 250 V AC/DC (N/O contact / N/C contact, observe the load curve) |
| Minimum switching voltage | 15 V AC/DC (N/O contact / N/C contact) |
| Limiting continuous current | 5 A (N/O contact, pay attention to the derating) |
| 100 mA (N/C contact) | |
| Maximum inrush current | 5 A (N/O contact) |
| 100 mA (N/C contact) | |
| Inrush current, minimum | 5 mA (N/O contact / N/C contact) |
| Sq. Total current | 25 A2(observe derating) |
| Interrupting rating (ohmic load) max. | 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W) |
| 192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W) | |
| 162 W (60 V DC, τ = 0 ms, N/C contact: 6 W) | |
| 66 W (110 V DC, τ = 0 ms, N/C contact: 11 W) | |
| 60 W (220 V DC, τ = 0 ms, N/C contact: 22 W) | |
| 1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA) | |
| Maximum interrupting rating (inductive load) | 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W) |
| 43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W) | |
| 41 W (60 V DC, τ = 40 ms, N/C contact: 6 W) | |
| 35 W (110 V DC, τ = 40 ms, N/C contact: 11 W) | |
| 48 W (220 V DC, τ = 40 ms, N/C contact: 22 W) | |
| Switching capacity | min. 75 mW |
| Mechanical service life | 10x 106cycles |
| Output fuse | 5 A T fuse (N/O contact) |
| 150 mA Fast-blow (N/C contact) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 185 g |
| Mounting position | any |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%) |
| Category | 4 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%) |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (21/22), (13/14) |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |