View larger
PSR-PS40-1NO-1DO-24DC-SC 2700398 PHOENIX CONTACT Coupling relay
PSR-PS40-1NO-1DO-24DC-SC
2700398
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Isolate control signals safely with the Phoenix Contact PSR-PS40-1NO-1DO-24DC-SC coupling relay, built for interface adaptation in industrial automation loops. Such devices provide galvanic separation between control systems and field hardware while handling basic switching tasks. Enquire through our RFQ process to receive current pricing and availability details.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): No
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): No
- Release-delay (EF001129): 0.2 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 6.8 mm
- Height (EF000040): 93.1 mm
More info
▲Key Commercial Data
| Orderkey | 2700398 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 283 (C-6-2017) |
| GTIN | 4046356912884 |
| Weight per Piece (excluding packing) | 123.900 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 70 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % (A1/A2) |
|---|---|
| 20.4 V DC ... 26.4 V DC | |
| Rated control supply current IS | typ. 50 mA (depending on load M1 +100 mA) |
| Power consumption at US | typ. 1.2 W |
| Inrush current | typ. 400 mA (Δt s) |
| Filter time | max. 2 ms (at A1-A2; test pulse width) |
| ≥ 100 ms (at A1-A2; test pulse rate) | |
| Protective circuit | Serial protection against polarity reversal 33 V suppressor diode |
Digital inputs
| Input name | Start circuit |
|---|---|
| Number of inputs | 2 (Non-safety-related start inputs: Y1/Y2) |
| Inrush current | < 10 mA |
| Current consumption | < 5 mA |
| Voltage at input/start and feedback circuit | 24 V DC -15 % / +10 % |
| Max. permissible overall conductor resistance | 150 Ω |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| Output description | 2 N/O contacts in series, without delay, floating |
| Number of outputs | 1 (safety-related N/O contacts: 13/14) |
| Contact type | 1 enabling current path |
| Contact material | AgSnO2 |
| Switching voltage | min. 12 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A (High demand) |
| 4 A (Low demand) | |
| Inrush current | min. 3 mA |
| max. 6 A | |
| Sq. Total current | 36 A2(observe derating) |
| Switching capacity | min. 60 mW |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 4 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) |
Alarm outputs
| Output description | PNP |
|---|---|
| Number of outputs | 1 (non-safety-related) |
| Voltage | approx. 22 V DC (Us- 2 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Short-circuit protection | no |
| Output fuse | 150 mA fast blow |
Times
| Typical pickup time at US | < 200 ms (when controlled via A1, automatic start) |
|---|---|
| Typical release time at US | < 35 ms (when controlled via A1) |
| Recovery time | 500 ms |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 123.9 g |
| Mounting position | vertical, horizontal, with front of module upward |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Operating voltage display | 1 x yellow LED |
| Status display | 2 x green LEDs |
| Indication | 1 x red LED |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | no |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 26 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 12 mm |
| Screw thread | M3 |
| Torque | 0.5 Nm ... 0.6 Nm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178, EN 60079-15 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV from control circuit, start circuit, signal output to the enabling current path; 4 kV / basic insulation between all current paths and housing |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ...150 Hz, 2g |
| Conformance | CE-compliant |
| UL, USA/Canada | cULus |
| Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X | |
| Class I, Div. 2, Groups A, B, C, D, T4 | |
| GL | C, EMC2 |
| Environmental simulation test | ISA-S71.04 (G3) |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |