View larger
PSR-PC20-1NO-1NC-24DC-SC 2700577 PHOENIX CONTACT Coupling relay
PSR-PC20-1NO-1NC-24DC-SC
2700577
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact PSR-PC20-1NO-1NC-24DC-SC coupling relay utilizes force-guided contacts to safely switch off industrial circuits in compliance with strict functional safety standards. Coupling relays provide reliable signal separation and output expansion within machine control panels.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Note on application Note on application: Only for industrial use
- Utilization restriction CCCex note: Use in potentially explosive areas is not permitted in China.
- Product type: Coupling relay
- Product family: PSRmini
- Application: Safe switch off
- Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Data management status Article revision: 07
- Times Typ. starting time with U s: < 100 ms (with U s when controlled via A1)
- Typical release time: < 35 ms (when controlled via A1)
- Recovery time: 500 ms
- Maximum power dissipation for nominal condition: 3.43 W (I L ² = 36 A²)
- Nominal operating mode: 100% operating factor
- Supply Designation: A1/A2
- Rated control circuit supply voltage U S: 20.4 V DC ... 26.4 V DC
- Rated control circuit supply voltage U S: 24 V DC -15 % / +10 %
- Rated control supply current I S: typ. 50 mA
More info
▲| Note on application | |
| Note on application | Only for industrial use |
| Utilization restriction | |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Product type | Coupling relay |
| Product family | PSRmini |
| Application | Safe switch off |
| High demand | |
| Low demand | |
| Ex | |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Data management status | |
| Article revision | 07 |
| Times | |
| Typ. starting time with Us | < 100 ms (with Uswhen controlled via A1) |
| Typical release time | < 35 ms (when controlled via A1) |
| Recovery time | 500 ms |
| Maximum power dissipation for nominal condition | 3.43 W (IL² = 36 A²) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, 6 kV reinforced insulation from control circuit, start circuit, confirmation current path, signal output to the enabling current path; 4 kV/basic insulation between all current paths and housing |
| Supply | |
| Designation | A1/A2 |
| Rated control circuit supply voltage US | 20.4 V DC ... 26.4 V DC |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Rated control supply current IS | typ. 50 mA |
| Power consumption at US | typ. 1.2 W |
| Inrush current | typ. 400 mA (Δt s) |
| Filter time | max. 2 ms (at A1-A2; test pulse width) |
| ≥ 100 ms (at A1-A2; test pulse rate) | |
| Protective circuit | Serial protection against polarity reversal; Suppressor diode 33 V |
| Supply | |
| Designation | 31/A2, TBUS |
| Diagnostic supply voltage UD | 24 V DC -15 % / +10 % |
| Input current at UD | 6 mA (at 31-A2 for UD; depending on load + 100 mA at M1 and 32) |
| Inrush current at UD | typ. 2.5 A (Δt D) |
| Protective circuit | Serial protection against polarity reversal; Suppressor diode 33 V |
| Relay: Enabling current path | |
| Output description | 2 N/O contacts in series, without delay, floating |
| Number of outputs | 1 (safety-related N/O contacts: 13/14 (13F/14)) |
| Contact switching type | 1 enabling current path |
| Contact material | AgSnO2 |
| Switching voltage | min. 12 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Switching capacity | min. 60 mW |
| Inrush current | min. 3 mA |
| max. 6 A (N/O contact 13/14) | |
| 4 A (N/O contact 13F/14) | |
| Switching capacity in accordance with IEC 60947-5-1 | 4 A (24 V (DC13); N/O contact 13/14) |
| 5 A (250 V (AC15); N/O contact 13/14) | |
| 4 A (250 V (AC15); N/O contact 13F/14) | |
| Limiting continuous current | 6 A (13/14 for high-demand) |
| 4 A (13F/14 with high/low demand, 13/14 with low demand) | |
| Sq. Total current | 36 A2(13/14, see to derating) |
| 16 A2(13F/14, see to derating) | |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 6 A gL/gG (N/O contact 13/14) |
| 4 A gL/gG (for low-demand applications) | |
| Relay: Confirmation current path | |
| Output description | 2 N/C contacts in series, without delay, not floating (reference ground: A2) |
| Number of outputs | 1 (safety-related N/C contacts: 31/32) |
| Contact switching type | 1 confirmation current path |
| Contact material | AgCuNi, + Au |
| Switching voltage | min. 20.4 V DC |
| max. 26.4 V DC | |
| Switching capacity | min. 20 mW |
| Inrush current | min. 1 mA |
| max. 100 mA | |
| Limiting continuous current | 100 mA |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 150 mA Fast-blow |
| Signal: M1 | |
| Output description | PNP |
| Number of outputs | 1 (non-safety-related) |
| Voltage | approx. 22 V DC (UD- 2 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Short-circuit protection | no |
| Output fuse | 150 mA fast blow |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Status display | 1 x LED (green) |
| Operating voltage display | 1 x yellow LED |
| Error indication | 1 x LED (red) |
| Width | 12.5 mm |
| Height | 112.2 mm |
| Depth | 114.5 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 0 |
| Safety data: EN 50156 | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 3 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -40 °C ... 70 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| ATEX | |
| Identification | II 3G Ex ec nC IIC T4 Gc |
| Certificate | UL 22 ATEX 2912X |
| IECEx | |
| Identification | Ex ec nC IIC T4 Gc |
| Certificate | IECEx UL 22.0037X |
| UL, USA/Canada | |
| Identification | cULus |
| Certificate | E140324 |
| UL Ex, USA / Canada | |
| Identification | Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X |
| Class I, Div. 2, Groups A, B, C, D, T4 | |
| Certificate | E360692 |
| CE | |
| Identification | CE-compliant |
| Environmental simulation test | |
| Identification | G3 |
| Certificate | ISA-S71.04 |
| CCC / China-Ex | |
| Identification | Ex ec nC IIC T4 Gc |
| Certificate | 2022122304115695 |
| DNV | |
| Identification | C, EMC2 |
| Certificate | 11253-14 HH |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | EN 60664-1, EN 60079-7, EN 60079-15 |
| Mounting type | DIN rail mounting |
| Assembly note | See derating curve |
| Mounting position | vertical, horizontal, with front of module upward |