A Phoenix Contact controller (ILC 171 ETH 2TX) functions as a centralized or distributed processing unit in industrial control systems, managing discrete machine operations and digital I/O signals. These programmable controllers execute automation logic to coordinate industrial processes, conveyor systems, and manufacturing equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Voltage type (supply voltage) (EF002991): DC
- Model (EF000010): Modular
- Processing time (1K, binary operation) (EF003004): 0.0015 ms
- Number of HW-interfaces industrial Ethernet (EF003020): 2
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 1
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces USB (EF003025): 0
- Number of HW-interfaces parallel (EF003026): 0
- Number of HW-interfaces wireless (EF006933): 0
- Number of HW-interfaces other (EF003027): 1
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital inputs (EF001992): 8
- Number of digital outputs (EF001993): 4
More info
▲Key Commercial Data
| Orderkey | 2700975 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 81 (C-6-2017) |
| GTIN | 4046356665513 |
| Weight per Piece (excluding packing) | 350.000 g |
| Custom tariff number | 85371091 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
Control system
| Engineering tool | PC WORX |
|---|---|
| PC WORX EXPRESS | |
| Programming languages supported | Programming in acc. with IEC 61131-3 |
| Diagnostics tool | DIAG+ |
| Configuration tool | Config+ Version 1.01 or later |
IEC 61131 runtime system
| Engineering tool | PC WORX |
|---|---|
| PC WORX EXPRESS | |
| Program memory | 512 kByte |
| Mass storage | 512 kByte |
| Retentive mass storage | 48 kByte (NVRAM) |
| Number of control tasks | 8 |
| Realtime clock | Yes |
Fieldbus function
| Amount of process data | max. 4096 Bit (INTERBUS) |
|---|---|
| max. 32768 Bit (internal Modbus /TCP client) | |
| Number of supported devices | max. 128 |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) |
| Number of devices with parameter channel | max. 24 |
| Number of supported branch terminals with remote bus branch | max. 3 |
Data interfaces
| Interface | Ethernet 10Base-T/100Base-TX |
|---|---|
| Number | 2 |
| Connection method | RJ45 socket |
| Transmission speed | 10/100 Mbps |
| Interface | INTERBUS local bus (master) |
| Number | 1 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kBaud / 2 MBaud (can be switched) |
| Interface | Parameterization/operation/diagnostics |
| Number | 1 |
| Connection method | 6-pos. MINI DIN socket (PS/2) |
| Transmission speed | max. 115.2 kbps |
Direct I/Os
| Input name | Digital inputs |
|---|---|
| Number of inputs | 8 |
| Connection method | Inline potential distributor |
| Connection technology | 2, 3, 4-wire |
| Description of the input | EN 61131-2 type 1 NPN/PNP |
| Output name | Digital outputs |
| Number of outputs | 4 |
| Connection method | Spring-cage connection |
| Connection technology | 2, 3, 4-wire |
| Maximum output current per channel | 500 mA |
Power supply
| Typical current consumption | 210 mA |
|---|---|
| Max. current consumption | 870 mA (370 mA communications power + 500 mA analog voltage supply) |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Residual ripple | ± 5 % |
| Power dissipation | max. 5 W |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | Noise emission test as per EN 61000-6-4 EN 55011 Class A |
| Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV |
| Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV |
| Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
| Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
| Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V |
| Vibration (storage/transport) | 5g |
| Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
Environmental Product Compliance
| REACh SVHC | 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4 |
|---|---|
| Lead 7439-92-1 | |
| China RoHS | Environmentally Friendly Use Period = 50 |