Phoenix Contact UC-WMC 7,5 (30X8) OG CUS 0824782 is a labeled conductor marker designed for clear circuit identification in complex industrial control panels. These components help technicians trace wiring, maintain accurate schematics, and ensure safety during troubleshooting.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Labeled conductor marker
- Type: Card form
- Data management status Article revision: 01
- Marking Number of individual labels: 6
- Number of individual labels per row: 2
- Identification technology: UV LED technology
- Mounting type: clip on
- RoHS compliant: yes
- Color: orange (RAL 2003)
- Material: PA
- Flammability rating according to UL 94: V2
- Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
- Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
- Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
- Components: free from silicone and halogen
- UV resistance Specification: ISO 4892-2:2013-03 (following)
More info
▲| Product type | Labeled conductor marker |
| Type | Card form |
| Data management status | |
| Article revision | 01 |
| Marking | |
| Number of individual labels | 6 |
| Number of individual labels per row | 2 |
| Identification technology | UV LED technology |
| Mounting type | clip on |
| RoHS compliant | yes |
| Color | orange (RAL 2003) |
| Material | PA |
| Flammability rating according to UL 94 | V2 |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 120 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
| Components | free from silicone and halogen |
| Test for substances that would hinder coating with paint or varnish | |
| Result | Test passed |
| UV resistance | |
| Specification | ISO 4892-2:2013-03 (following) |
| Result | Test passed |
| Test duration | 96 h |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 120 °C |
| Width | 8 mm |
| Length | 30 mm |
| External dimensions | |
| Outside diameter | 5 mm ... 7.5 mm |
| Wipe resistance | DIN EN 61010-1 (VDE 0411-1) |