View larger
ETD-BL-1T-230 2905813 PHOENIX CONTACT Timer relay
ETD-BL-1T-230
2905813
PHOENIX CONTACT
1 Pcs.
Automation > Timer relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact timer relay provides reliable time management for automated electrical systems, machine tools, and process control installations. Engineers use such modular timing elements to regulate operational phases and sequence dependent loads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Timer relay
- Operating mode: 100% operating factor
- Mechanical service life: 15x 10 6 cycles
- Data management status Article revision: 00
- Insulation characteristics Insulation: Basic insulation
- Overvoltage category: III
- Pollution degree: 2
- Service life electrical: 1x 10 5 cycles
- Nominal frequency: 48 Hz ... 63 Hz
- Nominal power consumption: 4 VA
- Test voltage relay winding/relay contact: 4 kV
- Nominal power consumption: 4 VA
- Input voltage range: 24 V AC/DC ... 240 V AC/DC -15 % ... +10 %
- Temperature coefficient, typical: ≤ 0.01 %/K
- Recovery time: 100 ms
- Function: E: With switch-on delay
More info
▲| Product type | Timer relay |
| Operating mode | 100% operating factor |
| Mechanical service life | 15x 106cycles |
| Data management status | |
| Article revision | 00 |
| Insulation characteristics | |
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
| Service life electrical | 1x 105cycles |
| Nominal frequency | 48 Hz ... 63 Hz |
| Nominal power consumption | 4 VA |
| Test voltage relay winding/relay contact | 4 kV |
| Nominal power consumption | 4 VA |
| Input voltage range | 24 V AC/DC ... 240 V AC/DC -15 % ... +10 % |
| Temperature coefficient, typical | ≤ 0.01 %/K |
| Recovery time | 100 ms |
| Function | E: With switch-on delay |
| Rs: With release delay and control contact | |
| Es: With switch-on delay and control contact | |
| Ws: With single shot leading edge and control contact | |
| Setting range time | 50 ms ... 1 h (5 time end ranges) |
| Basic accuracy | ± 1 % (of scale end value) |
| Setting accuracy | ≤ 5 % (of scale end value) |
| Repeat accuracy | ≤ 0.5 % ±5 ms |
| Control | |
| Connection name | Non-floating, terminals A1-B1 |
| Control pulse length | ≥ 50 ms (DC) |
| ≥ 100 ms (AC) | |
| Switching | |
| Contact switching type | 1 floating changeover contact |
| Maximum switching voltage | 250 V AC (in acc. with IEC 60664-1) |
| Interrupting rating (ohmic load) max. | 1250 VA (5 A / 250 V AC) |
| Output fuse | 5 A (fast-blow) |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Conductor cross section rigid | 0.5 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section AWG | 20 ... 14 |
| Tightening torque | 1 Nm ... 1 Nm |
| Status display | Green LED (POWER) |
| Yellow LED (relay active) |
| Width | 17.5 mm |
| Height | 89.5 mm |
| Depth | 65.5 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Ambient conditions | |
| Degree of protection (Housing) | IP40 (Housing) |
| Degree of protection (Connection terminal blocks) | IP20 (Connection terminal blocks) |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Permissible humidity (operation) | 15 % ... 85 % |
| CE | |
| Certificate | CE-compliant |
| UKCA | |
| Certificate | UKCA-compliant |
| UL, USA/Canada | |
| Identification | UL 508 Listed |
| Electromagnetic compatibility | Conformance with EMC directive |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Noise immunity | EN 61000-6-2 |
| Noise emission | EN 61000-6-3 |
| Standards/regulations | EN 50178 |
| Mounting type | DIN rail mounting |
| Assembly note | on standard DIN rail NS 35 in accordance with EN 60715 |
| Mounting position | any |