CB E1 24DC/6A NC P 2800919 PHOENIX CONTACT Electronic device circuit breaker
CB E1 24DC/6A NC P
2800919
PHOENIX CONTACT
1 Pcs.
Automation > Device circuit breaker
Over Current Protection
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Manage industrial load protection with the Phoenix Contact CB E1 24DC/6A NC P 2800919 electronic device circuit breaker. Electronic protection components offer fast and selective tripping characteristics to safeguard sensitive instrumentation against electrical faults. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles: 1
- Construction type: Plug
- Width: 12.3 mm
- Height: 45 mm
- Depth: 52 mm
- Operating voltage: 30 V
- Nominal current: 6 A
- Active current limitation x IN: 1.25
- Fuse type: Electronic
- Fail safe element: 10 A
- Switch-off time: 0.13 ms
- Max. capacitive load: 0.02 µF
- With remote signalling contact: No
- Ambient temperature during operating: -25 °C
More info
▲Key Commercial Data
| Orderkey | 2800919 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 323 (C-4-2017) |
| GTIN | 4046356690683 |
| Weight per Piece (excluding packing) | 30.600 g |
| Custom tariff number | 85362010 |
| Country of origin | DE (Germany) |
Dimensions
| Height | 45 mm |
|---|---|
| Width | 12.3 mm |
| Depth | 52 mm |
| Complete module height | 90 mm |
| Complete module width | 12.3 mm |
| Complete module depth | 77.3 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 50 °C (non-condensing) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Humidity test | 96 h, 95 % RH, 40 °C |
| Vibration (operation) | 3g (In accordance with IEC 60068-2-6, Test Fc) |
| Degree of protection | IP30 (Actuation area) |
General
| Installation instructions | When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor). Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC). Parallel connection of multiple circuit breakers is not permitted. |
|---|---|
| Flammability rating according to UL 94 | V0 |
| Mounting type | on base element |
| Color | gray |
| Number of positions | 1 |
| Degree of pollution | 2 |
| Type | Male |
Electrical data
| Fuse type | electronic |
|---|---|
| Rated surge voltage | 0.5 kV |
| Operating voltage | 24 V DC |
| 18 V DC ... 30 V DC | |
| Nominal current IN | 6 A |
| Active current limitation | typ. 1.25 x IN |
| Closed circuit current I0 | typ. 8 mA (When switched on) |
| typ. 17 mA (With alarm output) | |
| Power dissipation | 1.19 W (Nominal operation) |
| Temperature derating | 5 A (at 50 °C) |
| Tripping method | E (electronic) |
| Required backup fuse | not required, integrated failsafe element |
| Dielectric strength | max. 30 V DC (Load circuit) |
| Voltage drop | 130 mV (at IN) |
| Shutdown time load circuit | 130 ms (see time/current characteristic curve) |
| Undervoltage shutdown load circuit | < 14 V (typ. OFF) |
| > 17 V (typ. ON) | |
| Max. capacitive load load circuit | 20000 µF |
| Auxiliary type of contact | floating signal contact |
| Minimum auxiliary contact operating voltage | 10 V DC |
| Maximum auxiliary contact operating voltage | 30 V DC |
| Minimum auxiliary contact operating current | 10 mA |
| Maximum auxiliary contact operating current | 0.5 A |
Standards and Regulations
| Standards/specifications | UL 2367 UL recognized |
|---|---|
| UL 508 UL/C-UL listed | |
| EMV EN 61000-6-3 Interference emission | |
| EMV EN 61000-6-2 Noise immunity |