View larger
CHARX PS-M2/825DC/1000DC/30KW 1296467 PHOENIX CONTACT CHARX power basic, Fast charging module for mounting D..
CHARX PS-M2/825DC/1000DC/30KW
1296467
PHOENIX CONTACT
1 Pcs.
Automation > DC-power supply
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
CHARX power basic, Fast charging module for mounting D... from Phoenix Contact, model CHARX PS-M2/825DC/1000DC/30KW 1296467 PHOENIX CONTACT CHARX power basic, Fast charging module for mounting D.., is engineered for high-power DC electric vehicle charging infrastructure. Charging modules of this class manage heavy-duty power conversion to deliver rapid, regulated energy transfers. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- DC operation Input voltage range: 300 V DC ... 825 V DC
- Derating: < 650 V DC ... 300 V DC (46 W/V)
- Nominal input voltage range: 650 V DC ... 825 V DC
- Input current: 48 A (650 V DC)
- Inrush current limitation: < 60 A
- Insulation resistance: > 10 MΩ
- Supply system configuration: DC grid (DC±, PE)
- Efficiency: > 95 % (P Out >50%)
- Output voltage range: 30 V DC ... 1000 V DC
- Output current range: 0 A ... 100 A
- Nominal power: 30 kW
- Power dissipation standby: < 14 W
- Protection against overvoltage at the output (OVP): > 1040 V DC
- Derating: > 55 °C (3.2 A/K)
- Control deviation: < 0.5 % (Voltage deviation static load change 20% ... 100%)
- Switch-on delay: < 8 s
More info
▲| DC operation | |
| Input voltage range | 300 V DC ... 825 V DC |
| Derating | < 650 V DC ... 300 V DC (46 W/V) |
| Nominal input voltage range | 650 V DC ... 825 V DC |
| Input current | 48 A (650 V DC) |
| 38 A (825 V DC) | |
| Inrush current limitation | < 60 A |
| Insulation resistance | > 10 MΩ |
| Supply system configuration | DC grid (DC±, PE) |
| Efficiency | > 95 % (POut>50%) |
| Output voltage range | 30 V DC ... 1000 V DC |
| Output current range | 0 A ... 100 A |
| Nominal power | 30 kW |
| Power dissipation standby | < 14 W |
| Protection against overvoltage at the output (OVP) | > 1040 V DC |
| Derating | > 55 °C (3.2 A/K) |
| > 55 °C (1 kW/K) | |
| Control deviation | < 0.5 % (Voltage deviation static load change 20% ... 100%) |
| < 1 % (Current deviation Static load change 20 % ... 100 %) | |
| ± 0.2 % (Input voltage change ±20 %) | |
| Switch-on delay | < 8 s |
| Overshoot behavior | ± 3 % (Switch-on procedure) |
| Battery technology | Li-Ion |
| Input | |
| Designation | Input |
| Identification | DC IN: + / - / PE |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 1.5 mm² ... 16 mm² |
| 10 mm² (recommended) | |
| flexible | 1.5 mm² ... 16 mm² |
| 10 mm² (recommended) | |
| rigid (AWG) | 15 ... 5 (Cu) |
| 7 (recommended) | |
| Stripping length | 18 mm (rigid/flexible) |
| Output | |
| Designation | Output |
| Identification | DC OUT: + / - |
| Conductor connection | |
| Connection method | T-LOX knee lever connection |
| rigid | 10 mm² ... 50 mm² |
| 25 mm² (recommended) | |
| flexible | 16 mm² ... 50 mm² |
| 25 mm² (recommended) | |
| rigid (AWG) | 8 ... 0 (Cu) |
| 16 (recommended) | |
| Stripping length | 20 mm (10 mm² ... 25 mm² = 18 mm, 35 mm² ... 50 mm² = 20 mm) |
| Interface | CAN bus |
| Number of interfaces | 1 |
| Connection method | 2x RJ45 (pin assignment, CANopen standard) |
| Locking | Locking clip |
| Transmission physics | Twisted-Pair |
| Topology | Line (daisy-chain connection) |
| Transmission speed | 125 kbps |
| Transmission length | max. 20 m |
| Supported protocols | CAN 2.0B |
| Electrical isolation | yes (primary/secondary) |
| no (PE) | |
| Number of power modules as CAN bus devices | max. 48 (within one CHARX control controller) |
| Termination resistor | 120 Ω (Terminating the end device) |
| Electrical isolation between input and output | yes |
| Insulation voltage input/output | 2121 V DC |
| Insulation voltage input, output / housing | 2121 V DC |
| Insulation voltage input, output/signal, communication | 4242 V DC |
| Insulation voltage signal, communication/housing | 707 V DC |
| Product type | DC power module |
| Product family | CHARX power basic |
| MTBF (IEC 61709, SN 29500) | > 300000 h |
| Service life | 40000 h (40 °C) |
| 70000 h (40 °C, fan) | |
| Internal fan | yes |
| Flow direction | from front to back |
| Insulation characteristics | |
| Protection class | I |
| Pollution degree | 2 |
| Item dimensions | |
| Width | 483 mm |
| Height | 134 mm |
| Depth | 550 mm |
| Dimensional drawing | |
| Rack unit | 3 U |
| Mounting type | 19" rack mounting |
| Housing material | Zn-Al alloy |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Overtemperature protection (OTP) | > 75 °C |
| Maximum altitude | ≤ 4000 m (Derating >2000 m: 10% / 1000 m) |
| Permissible humidity (operation) | ≤ 95 % (non-condensing) |
| Noise level | < 60 dB (1 m) |
| Overvoltage category | |
| IEC 60664-1 | II |
| Electric vehicle conductive charging system - Part 1: General requirements | |
| Standard designation | Electric vehicle conductive charging system - Part 1: General requirements |
| Standards/specifications | IEC 61851-1 |
| Electric vehicle conductive charging system – Part 23: DC electric vehicle charging station | |
| Standard designation | Conductive charging systems for electric vehicles – Part 23: DC supply equipment for electric vehicles |
| Standards/specifications | IEC 61851-23 |
| EMC requirements for noise emission | EN 61000-6-3 |
| EMC requirements for noise immunity | EN 61000-6-1 |