View larger
CHARX PS/3AC/920DC/87.5KW 1162690 PHOENIX CONTACT CHARX power, Fast charging module for mounting DC charging..
CHARX PS/3AC/920DC/87.5KW
1162690
PHOENIX CONTACT
1 Pcs.
Automation > DC-power supply
Power Supplies (PS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact CHARX fast charging module, part number CHARX PS/3AC/920DC/87.5KW (1162690), is engineered for high-power DC electric vehicle charging infrastructure. High-capacity power conversion modules like this are deployed in commercial charging stations to efficiently transform three-phase grid power into high-voltage direct current.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- AC Operation Input Voltage Range: 3x 400V AC ±10%
- Frequency Range: 3x 50 Hz ... 60 Hz ±10%
- Input current: 3x 130 A
- Power Factor (cos phi): 0,99
- Total Distortion (THDi): < 3%
- Network Structure: TN-S, TN-C, TN-C-S, IT (PE) (Central Point Grounding & Insulation Monitoring)
- Yield: max. 97 %
- Output Voltage Range: 200 V DC ... 920 V DC ±1%
- Output current: max. 125 A
- Residual ripple of the output current: ≤ 1%
- Nominal power: 87.5 kW
- Dissipated Power: < 2650 W
- Power dissipated in standby: < 135 W
- Derating: > 40 °C ... 50 °C (Derating 2.5%/K)
- Parallel operation: yes (Provision)
- Parallel connection possible: Yes, up to 2 control cabinets
More info
▲| AC Operation | |
| Input Voltage Range | 3x 400V AC ±10% |
| Frequency Range | 3x 50 Hz ... 60 Hz ±10% |
| Input current | 3x 130 A |
| Power Factor (cos phi) | 0,99 |
| Total Distortion (THDi) | < 3% |
| Network Structure | TN-S, TN-C, TN-C-S, IT (PE) (Central Point Grounding & Insulation Monitoring) |
| Yield | max. 97 % |
| Output Voltage Range | 200 V DC ... 920 V DC ±1% |
| Output current | max. 125 A |
| Residual ripple of the output current | ≤ 1% |
| Nominal power | 87.5 kW |
| Dissipated Power | < 2650 W |
| Power dissipated in standby | < 135 W |
| Derating | > 40 °C ... 50 °C (Derating 2.5%/K) |
| Parallel operation | yes (Provision) |
| Parallel connection possible | Yes, up to 2 control cabinets |
| Battery technology | Li |
| Number of phases | 3 |
| Product Type | DC Power Module |
| Product Family | CHARX power basic |
| Hot-PLUG Connection | Yes |
| Ventilation | Yes |
| Insulation Properties | |
| Kind of protection | I |
| Degree of pollution | 2 |
| Item Dimensions | |
| Width | 536 mm |
| Height | 222 mm |
| Depth | 600 mm |
| Type of mounting | Rack mounting |
| Environmental conditions | |
| Protection Index | IP20 |
| Ambient Temperature (Service) | 0 °C ... 50 °C (Derating > 40 °C: 2.5%/K) |
| Ambient Temperature (Storage/Transport) | -25 °C ... 85 °C |
| Fixing height | ≤ 2000 m (Derating > 1000 m: 10%/1000 m) |
| Permissible air humidity (service) | 5 % ... 95% (non-condensing) |
| Noise level | approx. 72 dB (at full load) |
| Surge Category | |
| IEC 60664-1 | Ii |
| Conductive charging system for electric vehicles. Part 1: General Requirements. | |
| Denomination of standard | Conductive charging systems for electric vehicles; Part 1: General Requirements |
| Rules/Provisions | IEC 61851-1 |
| UL Data | |
| Surge Category | Ii |