View larger
CCV 2,5/ 6-GF-5,08 GYP26THRR56 1845438 PHOENIX CONTACT Housing base printed circuit board, nominal current: ..
CCV 2,5/ 6-GF-5,08 GYP26THRR56
1845438
PHOENIX CONTACT
140 Pcs.
Connectors > Printed circuit board connector
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Housing bases for printed circuit boards, such as this Phoenix Contact CCV 2,5/ 6-GF-5,08 GYP26THRR56 unit, provide structural support and electrical termination points on device mainboards. These base housings accept mating connectors to establish reliable pathways for control signals and power within automated machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Printed circuit board base housing
- Product Family: CCV 2.5/.. -GF
- Product Line: COMBICON Connectors M
- Construction: Suitable component for Through Hole Reflow
- Number of poles: 6
- Step: 5.08 mm
- Number of connections: 6
- Number of rows: 1
- Number of potentials: 6
- Clamping flange: Overhead clamping (thread)
- Pin Design: Linear Pin Arrangement
- Number of Solder Pins Per Potential: 1
- Data Maintenance Status Article Review: 01
- Nominal Current I N: 12 A
- Nominal voltage U N: 320 V
- Contact resistance: 1 mΩ
More info
▲| Product Type | Printed circuit board base housing |
| Product Family | CCV 2.5/.. -GF |
| Product Line | COMBICON Connectors M |
| Construction | Suitable component for Through Hole Reflow |
| Number of poles | 6 |
| Step | 5.08 mm |
| Number of connections | 6 |
| Number of rows | 1 |
| Number of potentials | 6 |
| Clamping flange | Overhead clamping (thread) |
| Pin Design | Linear Pin Arrangement |
| Number of Solder Pins Per Potential | 1 |
| Data Maintenance Status | |
| Article Review | 01 |
| Nominal Current IN | 12 A |
| Nominal voltage UN | 320 V |
| Contact resistance | 1 mΩ |
| Sizing voltage (III/3) | 250 V |
| Dimensioning transient voltage (III/3) | 4 kV |
| Dimensioning voltage (III/2) | 320 V |
| Dimensioning Transient Voltage (III/2) | 4 kV |
| Nominal voltage (II/2) | 400 V |
| Dimensioning transient voltage (II/2) | 4 kV |
| Type of mounting | THR welding/wave welding |
| Pin Design | Linear Pin Arrangement |
| bridle | |
| Tightening torque | 0.3 Nm |
| Processing Instructions | |
| Process | Reflow/Wave Soldering |
| Moisture Sensitive Level | MSL 1 |
| Classification Temperature Tc | 260 °C |
| Welding cycles. by reflux | 3 |
| Material data - contact | |
| Observation | WEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact material | Cu Alloy |
| Surface Characteristics | Galvanically tinned |
| Metal surface contact area (top layer) | Tin (3 - 5 μm Sn) |
| Metal Surface Contact Area (Middle Layer) | Nickel (1.3 - 3 μm Ni) |
| Metal surface weld area (top layer) | Tin (3 - 5 μm Sn) |
| Metal Surface Welding Area (Middle Layer) | Nickel (1.3 - 3 μm Ni) |
| Material data - housing | |
| Color (Housing) | Grey (7042) |
| Insulating material | LCP |
| Insulating material group | IIIa |
| CTI according to IEC 60112 | 175 |
| Flammability class according to UL 94 | V0 |
| Data on Welding Processes | Processing in reflow soldering processes in accordance with IEC 60068-2-58 or DIN EN 61760-1 (current version, respectively) Moisture Sensitive Level (MSL) = 1 according to IPC/JEDEC J-STD-020-C |
| Observation regarding the operation | According to DIN EN 61984, COMBICON connectors are connectors without switching power (COC). In the event of use as prescribed, they must not be plugged in or unplugged under voltage or under load. |
| Dimension Scheme | |
| Step | 5.08 mm |
| Width [w] | 40.59 mm |
| Height [h] | 14.6 mm |
| Length [l] | 8.57 mm |
| Overall Height | 12 mm |
| Weld Pin Length [P] | 2.6 mm |
| Temple Dimensions | 1 x 1 mm |
| Printed circuit board design | |
| Hole diameter | 1.6 mm |
| Eye Exam | |
| Test Specification | DIN EN 60512-1-1:2003-01 |
| Result | Approved Test |
| Dimensional Examination | |
| Test Specification | DIN EN 60512-1-2:2003-01 |
| Result | Approved Test |
| Resistance of the signs | |
| Test Specification | DIN EN 60068-2-70:1996-07 |
| Result | Approved Test |
| Polarization & Coding | |
| Test Specification | DIN EN 60512-13-5:2006-11 |
| Result | Approved Test |
| Used contact holder | |
| Test Specification | DIN EN 60512-15-1:2009-03 |
| Contact Holder Used Requirement >20 N | Approved Test |
| Forces when plugging in and unplugging | |
| Result | Approved Test |
| Number of cycles | 25 |
| Plug-in force approx. | 8 N |
| Power when unplugging by pole approx. | 6 N |
| Thermal Test Test Group C | |
| Test Specification | DIN EN 60512-5-1:2003-01 |
| Number of poles tested | 12 |
| Insulation resistance | |
| Test Specification | DIN EN 60512-3-1:2003-01 |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Creepage Lines & Air Isolation Distances | |
| Test Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulating material group | IIIa |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 175 |
| Sizing Insulation Voltage (III/3) | 250 V |
| Nominal transient voltage (III/3) | 4 kV |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 3 mm |
| Minimum creepage line value (III/3) | 4 mm |
| Sizing Insulation Voltage (III/2) | 320 V |
| Nominal transient voltage (III/2) | 4 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 3 mm |
| Minimum creepage line value (III/2) | 3.2 mm |
| Sizing Insulation Voltage (II/2) | 400 V |
| Nominal transient voltage (II/2) | 4 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 3 mm |
| Minimum creepage line value (II/2) | 4 mm |
| Vibration test | |
| Test Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| frequency | 10 - 150 - 10 Hz |
| Sweep speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Test duration per axis | 2.5 h |
| Test Directions | X, Y, and Z axes |
| Durability Test | |
| Test Specification | DIN EN 60512-9-1 (VDE 0687-512-9-1):2010-12 |
| Bearable shock voltage at sea level | 4.8 kV |
| Contact Resistance R1 | 1 mΩ |
| Contact Resistance R2 | 1 mΩ |
| Plug Cycles | 25 |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Climate Essay | |
| Test Specification | DIN EN ISO 6988:1997-03 |
| Corrosion fatigue | 0.2 dm3UNDER2in 300 dm3/40 °C/1 cycle |
| Thermal stress | 105 °C/168 h |
| Bearable AC voltage | 2.21 kV |
| Crash | |
| Test Specification | DIN EN 60068-2-27 (VDE 0468-2-27):2010-02 |
| Shock Type | Semi-sinusoidal |
| Acceleration | 30g |
| Duration of the crash | 18 ms |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Environmental conditions | |
| Ambient Temperature (Service) | -40 °C ... 105 °C (depending on the rating curve) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Dimension Scheme | |
| Type of packaging | 56 mm wide strap |
| Belt Width [W] | 56 mm |
| External Coil Measurements [W2] | 62.4 mm |
| Coil Diameter [A] | 330 mm |
| Outer packing type | Dry bag |
| ESD Level | (D) Electrostatically conductive |
| Test Specification | DIN EN 61340-5-1 (VDE 0300-5-1): 2008-07 |