View larger
CBMC E4 24DC/1-10A S-R 1065729 PHOENIX CONTACT Multi-channel electronic circuit breaker for protecting four ..
CBMC E4 24DC/1-10A S-R
1065729
PHOENIX CONTACT
1 Pcs.
Automation > Device circuit breaker
Over Current Protection
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Multi-channel electronic circuit breaker for protecting four .. serve as essential components in industrial control architectures to distribute power securely and prevent damage from overcurrent faults across multiple output channels. Technicians deploy these modular units within control cabinets to ensure selective channel tripping and reliable system uptime. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 1
- Width (EF000008): 36 mm
- Height (EF000040): 90 mm
- Depth (EF000049): 98 mm
- Operating voltage (EF000111): 30 V
- Nominal current (EF000001): 40 A
- Active current limitation x IN (EF011922): 0
- Fuse type (EF011923): Electronic
- Fail safe element (EF011924): 15 A
- Switch-off time (EF011925): 0.01 ms
- Max. capacitive load (EF011926): 0.045 µF
- With remote signalling contact (EF000422): No
- Ambient temperature during operating (EF007515): -25 °C
More info
▲Key Commercial Data
| Orderkey | 1065729 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 375 (C-4-2019) |
| GTIN | 4055626728810 |
| Weight per Piece (excluding packing) | 140.000 g |
| Custom tariff number | 85363030 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Humidity test | 96 h, 95 % RH, 40 °C |
| Altitude | ≤ 3000 m up to 52 °C (amsl (above mean sea level)) |
| ≤ 4000 m up to 46 °C (amsl (above mean sea level)) | |
| Shock (operation) | 30g (IEC 60068-2-27, Test Ea) |
| Vibration (operation) | 10 Hz ... 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc) |
| 57.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc) | |
| Degree of protection | IP20 |
General
| Flammability rating according to UL 94 | V-0 |
|---|---|
| Mounting type | DIN rail: 35 mm |
| Color | light grey RAL 7035 |
| Number of positions | 1 |
| Protection class | III |
| Type | DIN rail module, one-piece |
Electrical data
| Fuse type | electronic |
|---|---|
| Rated surge voltage | 0.5 kV |
| Operating voltage | 18 V DC ... 30 V DC |
| Rated voltage | 24 V DC |
| Rated current IN | max. 40 A DC (IN+) |
| max. 40 A DC (per terminal position when bridging additional devices via IN+) | |
| 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 A DC (adjustable per output channel) | |
| Measuring tolerance I | ± 15 % |
| Feedback resistance | max. 35 V DC |
| Fail-safe element | 15 A DC (per output channel) |
| Efficiency | > 99 % |
| Closed circuit current I0 | typ. 33 mA |
| Power dissipation | typ. 0.8 W (No-load operation) |
| < 9 W (Nominal operation) | |
| Module initialization time | 1.6 s |
| Waiting time after switch off of a channel | 5 s (at overload / short circuit) |
| Temperature derating | 24 A DC (at 60 °C) |
| 28 A DC (at 54°C) | |
| 32 A DC (at 47°C) | |
| 36 A DC (at 41 °C) | |
| 40 A DC (at 35 °C) | |
| Tripping method | E (electronic) |
| Required backup fuse | not required, integrated failsafe element |
| Dielectric strength | max. 35 V DC (Load circuit) |
| MTBF (IEC 61709, SN 29500) | 8403361 h (at 25°C with 21% load) |
| 3067484 h (at 40°C with 34.25% load) | |
| 534188 h (at 35°C with 100% load) | |
| Shutdown time load circuit | ≤ 10 ms (for short circuit > 2.0 x IN) |
| 1 s (1.2 ... 2.0 x IN) | |
| Undervoltage shutdown load circuit | ≤ 17.8 V DC (active) |
| ≥ 18.8 V DC (inactive) | |
| Surge voltage shutdown load circuit | ≥ 30.5 V DC (active) |
| ≤ 29.5 V DC (inactive) | |
| Max. capacitive load load circuit | 45000 µF (Depending on the current setting and the short-circuit current available) |
| Output voltage status output | 24 V DC |
| Output current status output | max. 0.04 A (Short-circuit-proof) |
| Stripping length | 10 mm |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Input voltage reset input | 7 V DC ... 30 V DC (Reset with falling edge) |
| Current consumption reset input | typ. 0.4 mA (at 24 V DC) |
| Pulse length reset input | ≥ 50 ms (High) |
| ≥ 50 ms (Low) | |
| Voltage reset input | < 5 V DC (Low state) |
| > 8 V DC (High state) | |
| Stripping length | 10 mm |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
Signaling
| Channel LED off | off (Channel switched off) |
|---|---|
| Channel LED green | lit (Channel switched on) |
| Channel LED yellow | lit (Channel switched on, channel load > 80% ) |
| flashing (Programming mode active) | |
| Channel LED red | lit (Channel switched off, over- or undervoltage active) |
| ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release) | |
| flashing (Channel switched off, ready to be switched back on, overload or short-circuit release) | |
| two flashes (Channel switched off, device total current limit 40 A exceeded) |
Connection data
| Connection name | Main circuit IN+ |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 15 mm |
| Conductor cross section solid | 0.2 mm² ... 10 mm² |
| Conductor cross section AWG | 24 ... 8 |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 4 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 6 mm² |
| Connection name | Main circuit IN- |
| Connection method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Connection name | Main circuit OUT+ |
| Connection method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Standards and Regulations
| Standards/specifications | EN 61000-6-2 |
|---|---|
| EN 61000-6-3 | |
| EN 60068-2-6 | |
| EN 60068-2-27 | |
| EN 60068-2-78 | |
| EN 50178 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
| eCl@ss 10.0.1 | 27140401 |
|---|---|
| eCl@ss 4.0 | 27141100 |
| eCl@ss 4.1 | 27141100 |
| eCl@ss 5.0 | 27141100 |
| eCl@ss 5.1 | 27141100 |
| eCl@ss 6.0 | 27141100 |
| eCl@ss 7.0 | 27141116 |
| eCl@ss 8.0 | 27141116 |
| eCl@ss 9.0 | 27141116 |
UNSPSC
| UNSPSC 13.2 | 39121410 |
|---|---|
| UNSPSC 18.0 | 39121410 |
| UNSPSC 19.0 | 39121410 |
| UNSPSC 20.0 | 39121410 |
| UNSPSC 21.0 | 39121410 |