View larger
SAC-8P-M 8MS/ 0,3-PUR/M 8FS SH 1404133 PHOENIX CONTACT Sensor/actuator cable
SAC-8P-M 8MS/ 0,3-PUR/M 8FS SH
1404133
PHOENIX CONTACT
1 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact SAC-8P-M 8MS/ 0,3-PUR/M 8FS SH Sensor/actuator cable provides compact connectivity for space-constrained industrial installations. Miniature sensor lines link densely packed components, miniature actuators, and compact controllers in modern automated equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 8
- Type of electrical connection, field-sided (EF005525): M8
- Type of plug-in contact, field sided (EF006269): Male (plug)
- Positioning cable feed, field-sided (EF005928): Straight
- Type of electrical connection, box-sided (EF005524): M8
- Type of plug-in contact, box-sided (EF008386): Female (bus)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 0.3 m
- Halogen free (EF000025): Yes
- With LED indication (EF005950): No
- Screened (EF000881): Yes
- Cable type (EF000081): Multi-core
- Vulcanize (EF004115): No
- Material contact body (EF008248): CuSn
- Rated current In (EF008250): 1.5 A
- Rated voltage (EF000228): 30 V
More info
▲Key Commercial Data
| Orderkey | 1404133 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 216 (C-2-2017) |
| GTIN | 4046356680448 |
| Weight per Piece (excluding packing) | 29.800 g |
| Custom tariff number | 85444290 |
| Country of origin | PL (Poland) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
|---|---|
| Degree of protection | IP65 |
| IP67 |
General
| Rated current at 40°C | 1.5 A |
|---|---|
| Rated voltage | 30 V AC |
| 30 V DC | |
| Number of positions | 8 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Standards/regulations | M8 connector IEC 61076-2-104 |
| Status display | No |
| Protective circuit/component | unwired |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | ≥ 100 |
| Torque | 0.2 Nm (M8 connectors) |
Material
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
Standards and Regulations
| Standard designation | M8 connector |
|---|---|
| Standards/regulations | IEC 61076-2-104 |
| Flammability rating according to UL 94 | HB |
Cable
| Cable type | PUR halogen-free black |
|---|---|
| Cable abbreviation | Li9YV1-C-V1-11Y |
| UL AWM style | 20549 |
| Conductor cross section | 8x 0.14 mm² (Signal line) |
| AWG signal line | 26 |
| Conductor structure signal line | 18x 0.10 mm |
| Core diameter including insulation | 1 mm ±0.02 mm (Signal line) |
| Thickness, insulation | ≥ 0.21 mm (Signal line) |
| ≥ 0.38 mm (Outer cable sheath) | |
| Wire colors | white, brown, green, yellow, gray, pink, blue, red |
| Overall twist | 8 wires around filler to the core |
| Length of twist, overall twist | 58 mm |
| Shielding | Tinned copper braided shield |
| Optical shield covering | 85 % |
| External sheath, color | black-gray RAL 7021 |
| External cable diameter D | 5.9 mm ±0.2 mm |
| Smallest bending radius, fixed installation | 29.5 mm |
| Smallest bending radius, movable installation | 59 mm |
| Number of bending cycles | 2000000 |
| Bending radius | 59 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Outer sheath, material | PUR |
| Material, filler | PE |
| Material conductor insulation | PP |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | 1 GΩ*km (at 20 °C) |
| Conductor resistance | 139 Ω/km (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V AC |
| Test voltage, cable | ≥ 3000 V AC (Spark test) |
| Test voltage Core/Shield | ≥ 2000 V AC (for 60 s) |
| Flame resistance | according to UL 758/1581 (horizontal) |
| in accordance with UL 758/1581 FT2 | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| Other resistance | hydrolysis and microbe resistant |
| Resistant to salt water | |
| Low adhesion | |
| abrasion-resistant | |
| partly UV-resistant in accordance with DIN EN ISO 4892-2-A | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -25 °C ... 80 °C (cable, flexible installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |