PHOENIX CONTACT SAC-4P-10,0-PUR/M 8FR SH SAC-4P-10,0-PUR/M 8FR SH 1521999 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-10,0-PUR/M 8FR SH 1521999 PHOENIX CONTACT Sensor/actuator cable

SAC-4P-10,0-PUR/M 8FR SH

1521999

PHOENIX CONTACT

1 Pcs.

Sensor/actuator cable Sensor/actuator cable, 4-pole, halogen-free PUR, greyish black RAL 7021, shielded, free cable end, to Elbowed connection female M8, cable length: 10 m Sensor/actuator cable, 4-position, PUR halogen-free, black-gray RAL 7021, shielded, free cable end, on Socket angled M8, coding: A, cable length: 10 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact sensor/actuator cable, part number SAC-4P-10,0-PUR/M 8SH, is commonly deployed in automated industrial systems to connect field devices, sensors, and actuators securely to control architecture. This shielded cordset transmits reliable signal and data traffic while protecting against electromagnetic interference in complex machinery setups. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Application: Standard
  • Number of positions: 4
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: HB
  • Seal material: NBR
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Contact carrier material: TPU GF
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
ApplicationStandard
Number of positions4
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayno
Status display presentNo

Connection data
Conductor connection
Tightening torque0.2 Nm (M8 connectors)

Connector
Connection 1
Typefree cable end
Connection 2
TypeSocket angled M8
Number of positions4
Coding typeA

Cable/line
Cable length10 m
PUR halogen-free black [PUR]
Dimensional drawing
Cable weight31 kg/km
UL AWM Style20549
Number of positions4
Shieldedyes
Cable typePUR halogen-free black [PUR]
Conductor structure signal line32x 0.10 mm
AWG signal line24
Conductor cross section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.02 mm (Signal line)
External cable diameter4.70 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black
Thickness, insulation≥ 0.21 mm (Core insulation)
approx. 0.50 mm (Outer cable sheath)
Overall twist4 wires, twisted
Optical shield covering80 %
Max. conductor resistancemax. 78 Ω/km (at 20 °C)
Insulation resistance≥ 100 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Smallest bending radius, fixed installation24 mm
Smallest bending radius, movable installation48 mm
Dynamic load capacity (bending)Max. bending cycles: 10000000, Bending radius: 48 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with UL 758/1581 FT2
DIN EN 60332-2-2 (20 s)
Resistance to oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
hydrolysis and microbe resistant
partly UV-resistant (in accordance with DIN EN ISO 4892-2-A)
Special propertiesFlexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Standards and regulations
Standard designationM8 connector
Standards/specificationsIEC 61076-2-104

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.