PHOENIX CONTACT CABLE-FLK14/AXIO/OE/0,14/4,0M CABLE-FLK14/AXIO/OE/0,14/4,0M 1369906 PHOENIX CONTACT Ready-made round cable. Control: Axioline Realtime I/O.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CABLE-FLK14/AXIO/OE/0,14/4,0M 1369906 PHOENIX CONTACT Ready-made round cable. Control: Axioline Realtime I/O..

CABLE-FLK14/AXIO/OE/0,14/4,0M

1369906

PHOENIX CONTACT

1 Pcs.

Ready-made round cable. Control: Axioline Realtime I/O. Connection 1: Individual conductors (8-poles) (The conductors are labeled and equipped with ferrules). Connection 2: Female IDC/FLK connection (1x 14-pole). Cable length: 4 m Round cable set; controller: Axioline Realtime I/O; connection 1: Single wires (8-position) (The wires are marked and fitted with ferrules); connection 2: IDC/FLK socket strip (1x 14-position); cable length: 4 m

Cables > PLC connection cable
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact ready-made round cable CABLE-FLK14/AXIO/OE/0,14/4,0M connects distributed I/O nodes to automation controllers, streamlining signal transmission in modular industrial systems. Factory-terminated assemblies ensure consistent mechanical and electrical integrity for control stations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: System cable
  • Ambient conditions Degree of protection: IP00
  • Degree of protection (Installation location): ≥ IP54 (Installation location)
  • Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
  • Ambient temperature (storage/transport): -40 °C ... 80 °C
  • Altitude: ≤ 2000 m
  • Operating voltage (AC): ≤ 30 V AC
  • Operating voltage (DC): ≤ 60 V DC
  • Nominal operating mode: 100% operating factor
  • Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
  • Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
  • Cable length: 4 m
  • 10X0.14 [PVC] UL AWM Style: 2464/1061
  • Number of positions: 10
  • Shielded: no
  • Cable type: 10X0.14 [PVC]

More info

▲
Technical data

Product properties
Product typeSystem cable

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP00
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient temperature (operation)-40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

Electrical properties
Operating voltage (AC)≤ 30 V AC
Operating voltage (DC)≤ 60 V DC
Nominal operating mode100% operating factor
Current (Per path, 50°C)≤ 1 A (Uncoiled, see derating)
Current (Per path, 70°C)≤ 0.6 A (Uncoiled, see derating)
Supported controller PHOENIX CONTACT Axioline
Suitable I/O cardAXL F DI16...
AXL F DI32...
AXL F DI64...
AXL F DO16...
AXL F DO32...
AXL F DO64...
AXL F DI16/DO16...
AXL F DI16/DO8...
AXL SE DI16...
AXL SE DO16...

Cable/line
Cable length4 m
10X0.14 [PVC]
UL AWM Style2464/1061
Number of positions10
Shieldedno
Cable type10X0.14 [PVC]
Conductor typeRound cable set
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section10x 0.14 mm²
Wire diameter incl. insulation1 mm ±0.03 mm
External cable diameter6.1 mm ±0.4 mm
Outer sheath, materialSemi-rigid PVC
External sheath, colorgray
Conductor materialTin-plated Cu litz wires
Cable resistance≤ 145 Ω/km (20 °C)
Insulation resistance≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation52 mm
Smallest bending radius, movable installation98 mm
Max. bending cycles5000
Halogen-freeno
Flame resistanceIEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1
Resistance to oilcan withstand occasional splashes (raw cable)
color code
IDC/FLK14 (1)() = black
IDC/FLK14 (2)() = brown
IDC/FLK14 (3)() = red
IDC/FLK14 (4)() = orange
IDC/FLK14 (5)() = yellow
IDC/FLK14 (6)() = green
IDC/FLK14 (7)() = blue
IDC/FLK14 (8)() = violet

Connection data
Cross section AWG(converted acc. to IEC)
Connection 1
Connection methodSingle wires
Stripping length (Sheath) 150 mm
Number of positions8
NoteThe wires are marked and fitted with ferrules
Connection 2
Connection in acc. with standardbased on IEC 60603-13
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions14
Conductor cross section AWG26
Insertion/withdrawal cycles> 50
Pitch2.54 mm

Notes
GeneralFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.