PHOENIX CONTACT CABLE-D-15SUB/F/OE/0,25/S/6,0M CABLE-D-15SUB/F/OE/0,25/S/6,0M 2926140 PHOENIX CONTACT Cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CABLE-D-15SUB/F/OE/0,25/S/6,0M 2926140 PHOENIX CONTACT Cable

CABLE-D-15SUB/F/OE/0,25/S/6,0M

2926140

PHOENIX CONTACT

1 Pcs.

Cable Shielded ready-made round cable; Connection 1: Single conductors (15-poles) (The conductors are labeled and equipped with ferrules. The braided screen protrudes from the separate cable end.); Connection 2: Female connection D-SUB (1x 15-poles); Cable length: 6 m Assembled shielded round cable; connection 1: Single wires (15-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 15-position); cable length: 6 m

Cables > PLC connection cable
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Configured as a shielded system cable, the Phoenix Contact CABLE-D-15SUB/F/OE/0,25/S/6,0M 2926140 terminates with an open end for flexible installation. Industrial signal cables bridge sub-assemblies and control units, offering reliable interference protection in complex automation layouts.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: System cable
  • Data management status Article revision: 02
  • Ambient conditions Degree of protection: IP20
  • Degree of protection (Installation location): ≥ IP54 (Installation location)
  • Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
  • Ambient temperature (storage/transport): -40 °C ... 80 °C
  • Altitude: ≤ 2000 m
  • Operating voltage (AC): ≤ 30 V AC
  • Operating voltage (DC): ≤ 60 V DC
  • Nominal operating mode: 100% operating factor
  • Current (Per path): ≤ 2 A (Uncoiled, see derating)
  • Cable length: 6 m
  • 15X0.25 [PVC] UL AWM Style: 2464/1061
  • Number of positions: 15
  • Shielded: yes
  • Cable type: 15X0.25 [PVC]

More info

▲
Technical data

Product properties
Product typeSystem cable
Data management status
Article revision02

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient temperature (operation)-40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

Electrical properties
Operating voltage (AC)≤ 30 V AC
Operating voltage (DC)≤ 60 V DC
Nominal operating mode100% operating factor
Current (Per path)≤ 2 A (Uncoiled, see derating)

Cable/line
Cable length6 m
15X0.25 [PVC]
UL AWM Style2464/1061
Number of positions15
Shieldedyes
Cable type15X0.25 [PVC]
Conductor typeAssembled shielded round cable
Conductor structure signal line14x 0.15 mm
AWG signal line24
Conductor cross section15x 0.25 mm²
Wire diameter incl. insulation1.2 mm ±0.05 mm
External cable diameter7.90 mm ±0.5 mm
Outer sheath, materialSemi-rigid PVC
External sheath, colorgray
Conductor materialBare Cu litz wires
Cable resistance≤ 80 Ω/km (at 20 °C)
Insulation resistance≥ 20 MΩ*km (at 20 °C)
Smallest bending radius, fixed installation67 mm
Smallest bending radius, movable installation126 mm
Dynamic load capacity (bending)Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter)
Halogen-freeno
Flame resistanceIEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1
Resistance to oilcan withstand occasional splashes (raw cable)
Color code
whiteD-SUB15 (1) = ()
brownD-SUB15 (2) = ()
greenD-SUB15 (3) = ()
yellowD-SUB15 (4) = ()
grayD-SUB15 (5) = ()
pinkD-SUB15 (6) = ()
blueD-SUB15 (7) = ()
redD-SUB15 (8) = ()
blackD-SUB15 (9) = ()
violetD-SUB15 (10) = ()
gray-pinkD-SUB15 (11) = ()
red-blueD-SUB15 (12) = ()
white-greenD-SUB15 (13) = ()
brown-greenD-SUB15 (14) = ()
white-yellowD-SUB15 (15) = ()

Connection data
Connection 1
Connection methodSingle wires
Stripping length (Sheath) 150 mm
Number of positions15
NoteThe wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.
Connection 2
Connection in acc. with standardIEC 60807-2
DIN 41652
Connection methodD-SUB socket strip
Screw threadUNC 4-40
Number of connections1
Number of positions15
Tightening torque0.2 Nm
Insertion/withdrawal cycles> 200
Pitch2.74 mm

Notes
Notes on operationNo additional touch protection is required when using a SELV/PELV voltage (≤30 V AC or 60 V DC).
Notes on operationFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.