Configured as a shielded system cable, the Phoenix Contact CABLE-D-15SUB/F/OE/0,25/S/6,0M 2926140 terminates with an open end for flexible installation. Industrial signal cables bridge sub-assemblies and control units, offering reliable interference protection in complex automation layouts.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: System cable
- Data management status Article revision: 02
- Ambient conditions Degree of protection: IP20
- Degree of protection (Installation location): ≥ IP54 (Installation location)
- Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m
- Operating voltage (AC): ≤ 30 V AC
- Operating voltage (DC): ≤ 60 V DC
- Nominal operating mode: 100% operating factor
- Current (Per path): ≤ 2 A (Uncoiled, see derating)
- Cable length: 6 m
- 15X0.25 [PVC] UL AWM Style: 2464/1061
- Number of positions: 15
- Shielded: yes
- Cable type: 15X0.25 [PVC]
More info
▲| Product type | System cable |
| Data management status | |
| Article revision | 02 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| -10 °C ... 70 °C (flexible installation) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Operating voltage (AC) | ≤ 30 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Nominal operating mode | 100% operating factor |
| Current (Per path) | ≤ 2 A (Uncoiled, see derating) |
| Cable length | 6 m |
| 15X0.25 [PVC] | |
| UL AWM Style | 2464/1061 |
| Number of positions | 15 |
| Shielded | yes |
| Cable type | 15X0.25 [PVC] |
| Conductor type | Assembled shielded round cable |
| Conductor structure signal line | 14x 0.15 mm |
| AWG signal line | 24 |
| Conductor cross section | 15x 0.25 mm² |
| Wire diameter incl. insulation | 1.2 mm ±0.05 mm |
| External cable diameter | 7.90 mm ±0.5 mm |
| Outer sheath, material | Semi-rigid PVC |
| External sheath, color | gray |
| Conductor material | Bare Cu litz wires |
| Cable resistance | ≤ 80 Ω/km (at 20 °C) |
| Insulation resistance | ≥ 20 MΩ*km (at 20 °C) |
| Smallest bending radius, fixed installation | 67 mm |
| Smallest bending radius, movable installation | 126 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Halogen-free | no |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| VDE 0842, Part 332-1-2 (raw cable) | |
| IEC 60332-3-22 (raw cable) | |
| UL VW-1 | |
| CSA FT-1 | |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Color code | |
| white | D-SUB15 (1) = () |
| brown | D-SUB15 (2) = () |
| green | D-SUB15 (3) = () |
| yellow | D-SUB15 (4) = () |
| gray | D-SUB15 (5) = () |
| pink | D-SUB15 (6) = () |
| blue | D-SUB15 (7) = () |
| red | D-SUB15 (8) = () |
| black | D-SUB15 (9) = () |
| violet | D-SUB15 (10) = () |
| gray-pink | D-SUB15 (11) = () |
| red-blue | D-SUB15 (12) = () |
| white-green | D-SUB15 (13) = () |
| brown-green | D-SUB15 (14) = () |
| white-yellow | D-SUB15 (15) = () |
| Connection 1 | |
| Connection method | Single wires |
| Stripping length (Sheath) | 150 mm |
| Number of positions | 15 |
| Note | The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end. |
| Connection 2 | |
| Connection in acc. with standard | IEC 60807-2 |
| DIN 41652 | |
| Connection method | D-SUB socket strip |
| Screw thread | UNC 4-40 |
| Number of connections | 1 |
| Number of positions | 15 |
| Tightening torque | 0.2 Nm |
| Insertion/withdrawal cycles | > 200 |
| Pitch | 2.74 mm |
| Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤30 V AC or 60 V DC). |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |