View larger
CABLE-2FLK24/2FLK24/DV/10,0M/S 2906959 PHOENIX CONTACT Cable
CABLE-2FLK24/2FLK24/DV/10,0M/S
2906959
PHOENIX CONTACT
1 Pcs.
Cables > PLC connection cable
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The CABLE-2FLK24/2FLK24/DV/10,0M/S 2906959 PHOENIX CONTACT Cable is a robust system cable designed to link industrial controllers with designated I/O modules safely. Factory-terminated multi-conductor cables ensure secure signal routing, reducing on-site wiring time and minimizing electrical interference in control panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: System cable
- Data management status Article revision: 02
- Ambient conditions Degree of protection: IP00
- Degree of protection (Installation location): ≥ IP54 (Installation location)
- Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m
- Operating voltage (AC): ≤ 30 V AC
- Operating voltage (DC): ≤ 60 V DC
- Nominal operating mode: 100% operating factor
- Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
- Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
- Supported controller EMERSON DeltaV Suitable I/O card: SE4053S2B11
- Cable length: 10 m
- 50X0.14 [PVC] UL AWM Style: 2464/1061
- Number of positions: 50
More info
▲| Product type | System cable |
| Data management status | |
| Article revision | 02 |
| Ambient conditions | |
| Degree of protection | IP00 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| -10 °C ... 70 °C (flexible installation) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Operating voltage (AC) | ≤ 30 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Nominal operating mode | 100% operating factor |
| Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) |
| Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
| Supported controller EMERSON DeltaV | |
| Suitable I/O card | SE4053S2B11 |
| SE4083S2B11 | |
| Cable length | 10 m |
| 50X0.14 [PVC] | |
| UL AWM Style | 2464/1061 |
| Number of positions | 50 |
| Shielded | yes |
| Cable type | 50X0.14 [PVC] |
| Conductor type | Assembled shielded round cable |
| Conductor structure signal line | 7x 0.16 mm |
| AWG signal line | 26 |
| Conductor cross section | 50x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| External cable diameter | 11.00 mm ±0.3 mm |
| Outer sheath, material | Semi-rigid PVC |
| External sheath, color | gray |
| Conductor material | Tin-plated Cu litz wires |
| Cable resistance | ≤ 145 Ω/km (at 20 °C) |
| Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Smallest bending radius, fixed installation | 114 mm |
| Smallest bending radius, movable installation | 205 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 18x outside diameter) |
| Halogen-free | no |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| VDE 0842, Part 332-1-2 (raw cable) | |
| IEC 60332-3-22 (raw cable) | |
| UL VW-1 | |
| CSA FT-1 | |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Cable type | Cable for one module |
| Connection 1 | |
| Connection in acc. with standard | based on IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 2 |
| Number of positions | 24 |
| Conductor cross section AWG | 26 |
| Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm |
| Connection 2 | |
| Connection in acc. with standard | based on IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 2 |
| Number of positions | 24 |
| Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |